Chamberlain Swing GATE Installation And Operation Instructions Manual page 16

Swing gate operator swing gate operator (-68 board)
Table of Contents

Advertisement

2. RIGHT GATE (COUNTERCLOCKWISE OPEN) ADJUSTMENTS
"Left Reverse" Adjustment (R81)
1. Initiate opening the gate.
2. Wait 4 to 5 seconds, then lightly "tug"against the edge of the gate to simulate an obstacle.
3. If the gate does not stop, reclose the gate and adjust the pot slightly counterclockwise.
4. Repeat steps 1-3 until the gate stops when tugged and has the desired sensitivity.
"Right Reverse" Adjustment (R78)
1. Open the gate fully, then initiate closing the gate.
2. Wait 4 to 5 seconds, then lightly "bump" the leading edge of the gate to simulate an obstacle.
3. If the gate does not stop or back up, reopen the gate and adjust the pot slightly
counterclockwise.
4. Repeat steps 1-3 until the gate stops or backs up when bumped and has the desired
sensitivity.
3. INRUSH CURRENT ADJUSTMENT (R119)
1. Turn the pot fully counterclockwise.
2. Initiate opening the gate.
3. If the gate stops due to a fault condition, slightly adjust the pot clockwise.
4. Repeat steps 2 and 3 until the gate cycles without a fault.
5. Open the gate fully, then initiate closing the gate.
6. If the gate stops or backs up due to a fault condition, slightly adjust the pot clockwise.
7. Repeat steps 6 and 7 until the gate cycles without a fault and has the desired sensitivity.
Rev C
Doc 6001242 (01-20273)
15 of 53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Liftmaster sw 2000-b1

Table of Contents