To Connect The Main Power Supply - Daikin EBLQ-C2V3 Installer's Reference Manual

Altherma monobloc compact outdoor unit
Table of Contents

Advertisement

a
≥25 mm
a
Low voltage cable
b
High voltage cable
c
Power supply cable
NOTICE
The distance between the high voltage and low voltage
cables should be at least 25 mm.
Routing
Possible cables (depends on the installed
options)
a
▪ Interconnection cable to domestic hot
water tank
Low voltage
▪ Remote outdoor sensor (option)
b
▪ Normal kWh rate power supply
High voltage
▪ Preferential kWh rate power supply
▪ Shut-off valve (field supply)
c
▪ Main power supply
Main power supply
4 Inside the unit, route the wiring as follows:
a
a
Low voltage wiring
b
High voltage wiring + main power supply
5 Make sure that the cable does NOT come in contact with sharp
edges or hot gas piping.
6 Install the switch box cover.
INFORMATION
When installing field supply or option cables, foresee
sufficient cable length. This will make it possible to remove/
reposition the switch box and gain access to other
components during service.
CAUTION
Do NOT push or place redundant cable length in the unit.
EBLQ05+07C2V3
Daikin Altherma monobloc compact outdoor unit
4P598847-1 – 2019.10
b
c
b
6.5.5

To connect the main power supply

1 Connect the main power supply.
In case of normal kWh rate power supply
X6Y
A2P
X1A
X5M
X3M
1
GND
2
L
3
N
a
Interconnection cable (=main power supply)
In case of preferential kWh rate power supply
A2P
X5M
X3M
J8
1
GND
2
L
3
N
a
Interconnection cable (=main power supply)
b
Normal kWh rate power supply
6 Installation
X6YA
X19A
1
2
3
X4M
a
1 2 3
X6Y
X6YB
X6YA
X19A
X1A
1
2
3
X4M
b
a
1 2
1 2 3
S2S
c
11
12
Installer reference guide