PROGRAMMING THE RADIO RECEIVER

SET SECURITY MODE
The Universal Receiver can be used with up to 15 rolling code
transmitters or passwords in HIGH security mode. Alternately, it
can be used with up to 31 of any type transmitter in NORMAL
security mode, including any combination of rolling code, billion
code, or dip switch remotes.
The jumper must be set at the HIGH position for the receiver to
operate in HIGH security mode. It must be set at NORMAL
position to operate at the NORMAL mode (Figure 1).
When changing from NORMAL to HIGH security mode, any
previous transmitter codes must be erased. Repeat Steps 2 and 3
in the Programming Section below to reprogram the receiver for
each remote control transmitter in use.
The receiver is factory set at HIGH.
SET OUTPUT DURATION
WARNING
WARNING
To prevent possible SERIOUS INJURY or DEATH, the use of
CONSTANT OPERATION on residential openers is PROHIBITED.
CAUTION
For commercial applications, the receiver can be set for either
constant or momentary closure on the output contacts. Use of
constant closure is prohibited on residential garage door openers
because it overrides the safety reversal devices.
With the jumper in the "M" (Momentary) position, the contacts will
close for 1/4 second regardless of the length of radio
transmission. With the jumper in "C" (Constant) position, the
contacts will stay closed as long as the radio continues
transmitting (Figure 2).
The receiver is factory set at M.
PROGRAMMING THE REMOTE TO THE RECEIVER
AVERTISSEMENT
1. Pry open the front panel of receiver case with a coin or a
screwdriver. Re-connect power to operator (Figure 3).
2. Press and release the "learn" button on the receiver. The learn
ATTENTION
indicator light will glow steadily for 30 seconds.
3. Within 30 seconds, press and hold the button on the hand-held
remote that you wish to operate your gate operator.
The opener will now operate when the push button on either the
receiver or the remote control is pressed.
Repeat Steps 2 and 3 for each remote control that will be used to
operate the gate operator.
TO ERASE ALL REMOTE CONTROL CODES
Press and hold the "learn" button on the receiver panel until the
indicator light turns off (about 6 seconds). All remote codes are
now erased. Then follow the steps above to reprogram each
remote control.
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of
this receiver and/or transmitter are prohibited, except for changing the code setting or replacing
the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
ADVERTENCIA
P R O G R A M M I N G
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing the receiver.
To prevent possible SERIOUS INJURY or DEATH from a moving
gate or garage door:
• ALWAYS keep remote controls out of reach of children.
NEVER permit children to operate, or play with remote control
transmitters.
• Activate gate or door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to door travel.
• ALWAYS keep gate or garage door in sight until completely closed.
NEVER permit anyone to cross path of moving gate or door.
FIGURE 1
Security Mode
Terminals
FIGURE 2
CONSTANT
OPERATION
Output
Duration
Terminals
FIGURE 3
OPENING RECEIVER
Connect
Antenna
19
WARNING
WARNING
CAUTION
AVERTISSEMENT
Jumper
ATTENTION
HIGH
SECURITY MODE
Jumper
AVERTISSEMENT
ADVERTENCIA
AVERTISSEMENT
PRECAUCIÓN
Indicator Light
OPEN RECEIVER
24V
12V
ADVERTENCIA
Security Mode
Jumper
Terminals
WARNING
WARNING
NORMAL
SECURITY MODE
Jumper
MOMENTARY
OPERATION
Output
Duration
Terminals
Learn Button
Output Duration
C
P2
Terminals
M
Security Mode
Power Supply
Jumper

Advertisement

Table of Contents
loading

Table of Contents