Summary of Contents for Chamberlain LiftMaster Professional HS670
Page 1
MODEL HS670 EAVY YDRAULIC LIDE PERATOR 2 YEAR WARRANTY Serial # ________________________ (located on electrical box cover) MODEL HS670 IS FOR VEHICULAR PASSAGE GATES ONLY AND Installation Date __________________ IS NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE...
Drive wheels are constructed of polyurethane material on a steel which are 24 VDC. The power required for operation is rectified hub and have a hardness factor of 95. HS670 1HP = 1-1/2" wide, from 24 VAC. 6" diameter; HS670 2HP= 2" wide, 6" diameter.
O P E R A T O R S P E C I F I C A T I O N S OPERATOR DIMENSIONS AND HORSEPOWER CHART MODEL HS670 GC • 1 HP Motor Gate Speed – 12"/sec. Maximum Gate Weight – 3000 lbs.
SAFETY ACCESSORY SELECTION UL325 ENTRAPMENT PROTECTION REQUIREMENTS All UL325 compliant LiftMaster gate operators will accept external entrapment protection devices to protect people from motorized GATE OPERATOR ENTRAPMENT PROTECTION gate systems. UL325 requires that the type of entrapment...
O P E R A T O R W A R N I N G S SAFETY INSTALLATION INFORMATION 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application. 2.
O P E R A T O R W A R N I N G S SUGGESTED ENTRAPMENT PROTECTION DEVICE LOCATIONS GATE SYSTEM (COMMERCIAL SLIDE GATE) Open Sentex Telephone Entry Edge System/Access Control Photo Eye For Open Cycle Close Edge Run Twisted Wire STREET From Loop...
O P E R A T O R W A R N I N G S SAFETY PRECAUTIONS FOR OPEN ROLLER GATES Gate Edge on Fence AND ORNAMENT “GRILL TYPE” GATES Gate Edge on Gate Edge on Post for Open Direction Rear of Gate for Leading Edge of Gate Open Direction...
I N S T A L L A T I O N NOTES: Installation shown is for a right-handed unit (on right side of gate opening when inside looking out). Left-handed is opposite. For left-handed conversion, see page 17. If there is suitable existing concrete at area of unit mounting, use dimensioning procedure described in step 1.
I N S T A L L A T I O N Important: Do Not VENT CAP Use Cover Handles To Move Unit 1. Remove the threaded plug from the pump tank. 2. Install the vent cap. NOTE: Never run the operator without the vent cap installed. LIMIT SHOES Loosen Screw To NOTE: The limit shoes are slotted, so minor adjustments may be...
IMPORTANT: Upper Drive Wheel If using the LiftMaster drive rail, make sure that the drive rail guide wheel is positioned properly. Separator Bolt It is very important that the suspension system is adjusted (Use 9/16"...
WARNING W I R I N G WARNING WARNING To reduce the risk of SEVERE INJURY or DEATH: • DO NOT install any wiring or attempt to run the operator without consulting the wiring diagram. We recommend that • ANY maintenance to the operator or in the area near the you Install an optional reversing edge BEFORE proceeding with operator MUST not be performed until disconnecting the the control station installation.
W I R I N G ON/OFF SWITCH POWER WIRING On/Off Switch NOTES: Before running power wiring refer to wiring specifications on Cover previous page for correct wire gauges. Secure all electrical power connections inside the disconnect Wire Nut switch electrical box. Refer to electrical wiring diagram on pages Connections (see instructions) 30 and 31.
A D J U S T M E N T RPM SENSOR (HALL EFFECT) ADJUSTMENT WARNING WARNING NOTE: Normally the RPM sensor (Hall effect) does not need adjustment, but may go out of alignment due to shipping To reduce the risk of SEVERE INJURY or DEATH: vibration or rough handling.
P R O G R A M M I N G UL325 ENTRAPMENT PROTECTION GL Controller Board Force Control PRIMARY ENTRAPMENT PROTECTION ADJUSTMENTS Max. Force Control Set the force control pot such that the unit will complete a full cycle of gate travel but can be reversed off an obstruction without applying an unreasonable amount of force.
P R O G R A M M I N G CONTROL BOARD ILLUSTRATION Connector Master/Second (J4) Connector Main Terminal DIP Switch Wiring (J1) Master/Second (S4) Timer to Close Force Adjustment DIP Switch (S2) DIP Switch (S1) Diagnostic LED Limit LEDs Connector (J2) Programming Port (factory use only)
P R O G R A M M I N G PROGRAM SETTINGS (DIP SWITCH S1) NOTE: For all S1, S2 and S4 switch settings to take effect, the Save Mode switch must be set to the off position. TIMER TO CLOSE TIMER TO CLOSE ENABLE This switch (S1-1) enables the auto close timer.
Page 18
NOTES: • Do not run Master/Second communication wiring in the same conduit as the power and control wiring. HS670 STREET • The Second unit will require a normally close stop circuit for proper system operation.
P R O G R A M M I N G PROGRAMMING THE RADIO RECEIVER WARNING WARNING SET SECURITY MODE To prevent possible SERIOUS INJURY or DEATH from The Universal Receiver can be used with up to 15 rolling code electrocution: CAUTION transmitters or passwords in HIGH security mode.
SAMS OPERATION SAMS WIRING 1. When an authorized vehicle accesses the gate system, the 1. Install conduit between the BG770 and the HS670 for SAMS SAM system responds by first opening the gate farthest from control wiring. the vehicle, the swing or slide gate.
O P T I O N A L C O N T R O L D E V I C E S ACCESSORY WIRING 2 3 4 7 8 9 10 11 12 13 14 STOP/RESET AUXILIARY CONTROL WIRING Terminals 6 & 5 (Com) - Open These terminals are intended for use as a general open control.
O P T I O N A L C O N T R O L D E V I C E S CONTROL CONNECTION DIAGRAMS J1 TERMINAL BLOCK 9 10 11 12 13 14 Soft Open Input (N.O.) 9 10 11 12 13 14 16 17 18 19 20 21 22 23 24 25 26 27 28 Hard Close...
8. Disconnect ALL power BEFORE performing ANY activates the non-contact sensors. After adjusting the maintenance. force or the limit of travel, retest the gate operator. 9. ALL maintenance MUST be performed by a LiftMaster SEMENT AVERTISSEMENT Failure to adjust and retest the gate operator properly professional.
T R O U B L E S H O O T I N G GL BOARD FEATURES Force Control DIAGNOSTICS (LEDS AND CODES) There are three diagnostic LEDs. Two red LEDs (OL, CL) are indicators for the open and close limits. The LEDs are illuminated when the limit switch contacts are closed.
T R O U B L E S H O O T I N G FAULT POSSIBLE CAUSE OPERATOR FAILS TO RUN 1) No stop control ➤ Check the green LED (D17) on GL board. If the green LED is off, check to make sure a stop control has been installed across terminals TB1-3 and TB1-5 of the Terminal Strip.
Page 26
T R O U B L E S H O O T I N G FAULT POSSIBLE CAUSE MASTER OR SECOND ➤ 1) Failure to cycle power after setup The power to each unit must be cycled in order to initiate proper OPERATOR IS NOT master/second communication if the operators were previously in FUNCTIONING PROPERLY...
T R O U B L E S H O O T I N G HYDRAULIC SYSTEM TROUBLESHOOTING (A) BYPASS VALVE: SYMPTOM POSSIBLE CAUSES It MUST be in the “automatic” position (horizontal). If it is in the manual position, no fluid gets to the drive motors, so UNIT SOUNDS LIKE IT IS A, B, F, H or I they won’t turn.
2HP (2" w. x 6" dia.). Circumference of both: 18.84" The pump on the HS670 has a built in relief valve. If the P.S.I. Both have a hardness of approximately 70 “A” shore. should exceed its factory setting, it will bleed off the excess. The HS670-100 is set at approximately 600 P.S.I.
Page 29
T R O U B L E S H O O T I N G HYDRAULIC DON’TS One Wrench To Must Be Clean, Hold This Fitting 1. DO NOT use only one wrench to lighten hose swivel fittings. No Pipe Dope Use two wrenches, one to tighten and one to hold back opposite fitting.
S I N G L E P H A S E W I R I N G D I A G R A M 01-G10028-1 EMMERSON MOTOR CONNECTIONS BALDOR MOTOR CONNECTIONS OVERLOAD (SEE NOTE 6) (LEFT) (RIGHT) NOTES: 1. Transformer primary voltage same as operator line voltage 24V secondary 60VA. 2.
T H R E E P H A S E W I R I N G D I A G R A M 01-G10028-3 (LEFT) (RIGHT) NOTES: 1. Transformer primary voltage same as operator line voltage 24V secondary 60VA. 2. Wire color: 230V orange, 460V violet. 3.
COMPLETE ELECTRICAL BOX REPLACEMENT KITS To order a complete electrical box replacement kit, add a K- prefix to the model number of your operator. For example: HS670-100-21 (Operator) = K-HS670-100-21 (Electrical Box Kit) INDIVIDUAL PARTS AND KITS ITEM PART #...
I L L U S T R A T E D P A R T S INDIVIDUAL PARTS AND KITS ITEM PART # DESCRIPTION NOTES PROVIDED IN KIT K20-1100 Motor, 1HP 115/230V 1PH 1HP 1PH Units Individual Part K20-3100C-4 Motor, 1HP 230/460V 3PH 1HP 3PH Units K20-3200C-4 Motor, 2HP 230/460V 3PH...
W A R R A N T Y P O L I C Y LIFTMASTER ® TWO YEAR LIMITED WARRANTY The Chamberlain Group, Inc. warrants to the final purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase.
HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA For installation and service information, call our TOLL FREE number: 1-800-528-2806 www.liftmaster.com When ordering repair parts please supply the following information: PART NUMBER DESCRIPTION MODEL NUMBER ADDRESS ORDER TO: THE CHAMBERLAIN GROUP, INC.