10. Temporary Switch
The temporary switch is used to operate the air conditioner temporarily when the wireless remote control
G
is lost or faulty.
The air conditioner operates in the previous mode at the previously set temperature. However, when the
G
power switch is set to OFF, it starts automatic operation.
11. Indoor Fan Motor Feedback Circuit
<Exp. of circuit wave>
G
Fan
motor will receive signal thru CN2 with VDC (Motor Drive Voltage), VCC (Motor Controller Power
G
Supply), VSC (RPM Instruction) motor WCC return the FG sinal under frequency RPM.
The circuit produces fan
G
motor speed.
CAUTION 1
Indoor fan motor circuit will be connected with primary
power source line and please take care of the
electrical shock.
0301E (30CH6) pg 47-68
5V
Temporary
switch
R609
0V
20V
I
O
IC201
G
ZD201
0V
R233
motor drive from 340V DC supplied from the indoor unit and controls the fan
54
TEMPORARY SW
44
MICRO COMPUTER
Fig. 10-1
340V
5V
15V
PC201
R501
5V
Q502
PC202
Q503
0V
0V
Fig. 11-1
Fig. 11-2
CAUTION 2
Please do not disconnect the fan motor connector during
running due to the high voltage supply, it will cause the
damage at fan motor and PWB.
– 54 –
16/12/05, 2:49 PM
CN2
VDC
1
0V
GND
3
VCC
FM
4
VS
5
FG
6

Advertisement