Hitachi RAS-30CH6 Service Manual page 41

Table of Contents

Advertisement

Operation mode
No.
Fan
Cooling
Control function
Set circulation velocity
Set circulation velocity
Set
temperature
Start/stop switch
Sleep key
Operation lamp
Timer lamp
• The set temperature
• The operation is
after sleep shift in
switched OFF
7
sensor dehumidification
at the set time.
operation is limited
by 16°C.
Notes:
• 60 minutes after the sleep key is switched on, sleep operation
is started.
• When the sleep key is switched on during OFF timer operation,
the OFF timer will be canceled.
Preheating
8
operation
T
1
Fan relay H
Power relay
Stick relay
Outside fan relay
Defrosting
9
(including automatic
Operation lamp
fresh defrosting).
Fan relay S
Power relay
Stick relay
Outside fan relay
Operation lamp
0301E (30CH6) pg 43
1
Sensor dehumidification
LO (sleep operation)
Set
Set circulation
temperature
velocity
2 deg up
Start/stop switch
60 minutes
60 minutes
Sleep key
Operation lamp
Timer lamp
• When the sleep key is switched on during OFF timer operation, the OFF timer will be cancelled.
Set
temperature
Set circulation
velocity
Start/stop switch
Sleep key
Operation lamp
Sleep key
Timer lamp
• When the sleep key is switched on during ON after a timer reservation, sleep operation will be started.
"Strong" circulation
Start/stop switch
Thermostat signal
Preheating signal
Fan relay H
Fan relay L
Fan relay S
Power relay
2 sec
Hot keep lamp
Notes:
• Even when the preheating signal is not given as input, heating operation is started when
3 minutes have passed for T.
• Preheating operation is executed at the time of operation start and after completion
of defrosting, and at all other times, there is no operation, independent of the preheating signal.
T
E
30 sec
30 sec
Start/stop switch
Indoor heat exchanger
Defrosting signal
thermistor temperature
Preheating signal
Fan relay H
Fan relay L
Fan relay S
2 sec
Power relay
Stick relay
External fan relay
Reversing valve relay
10 sec
Heater relay
Operation lamp
Hot keep lamp
Min. 3 minutes
TA
10 min.
(Reverse cycle defrosting)
+0
min.
-1
TB
30 sec
(Silencing period)
TC
30 sec
(Cycle balancing time)
TE
50 min.
(Defrosting prohibition
+0
min.
-5
time)
Heating
Automatic
• Sleep operation is executed
5 deg down
for each operation mode.
60 minutes
LO (sleep operation)
• Sleep operation is executed
5 deg down
for each operation mode.
60 minutes
LO (sleep operation)
• At the time of heating
15sec 30 sec 30 sec
30 sec 30 sec
operation mode, the same
operation as for heating
is executed.
2 sec
3 minutes
T
Defrosting
• Defrosting of each operation
start
Completion
mode is executed.
15 minutes-T
E
30 sec
30 sec
15 sec
15 sec
2 sec
10 sec
T
A
T
B
T
C
T
A
30 sec 60 sec
30 sec 60 sec
3 minutes
• For the time TE after start of heating operation, defrosting will not be
executed even when the defrosting signal is given as input.
• When the reserve cycle defrosting TA has continued for the time
shown in the table on the left, the operation advances to TB and TC
independent of the defrosting signal.
• When the power relay becomes ON after expiration of the time TE,
defrosting will be started immediately with input of the defrosting signal.
• Once defrosting has been completed, the defrosting signal is not
accepted for the time TE.
• When a defrosting signal has been given as input at the time of stop
by means of the start/stop switch or at the time of OFF timer count-up,
defrosting is executed before operation stop.
• The defrosting signal is not accepted at the time of overload input.
16/12/05, 2:47 PM
Table 1 Specifications
Other detailed specifications
1.
When the room temperature rises
Item
within 3 minutes after thermostat
Operation switching
Automatic
Yes
OFF during cooling operation with
Heating
Yes
automatic velocity, the blowing
Fan
Yes
velocity changes in the order of
S
L
Sensor
Yes
dehumidification
at the time of thermostat ON.
Cooling
Yes
2.
In case of Tele. control input during
stopped ON timer, operation will
Temporary switch
Yes (automatic)
be started at that time and the timer
Service switch
Heating
NO
will be cleared.
Cooling
Yes
Nice temperature reservation
Yes
3.
In case of Tele. control input during
operation of the OFF timer, the
Automatic fresh defrosting
Yes
operation will be stopped at that
Defrosting
Yes
time and the timer will be cleared.
Pd cut 1
Yes
Pd cut 2
Yes
4.
Even when operation stop is
Pd cut 3
Yes
executed at the time of outside fan
Heating load reduction
Yes
OFF by overload, automatic fresh
External fan relay
defrosting will not be executed.
Yes
Reversing valve relay
Yes
5.
In case of switching to "Heating"
Reversing valve lock protection
Yes
during
Sleep circuit
Yes
operation, the operation will be
Heater operation at the time of sensor
No
continued as it is when the
dehumidification
thermostat is ON. 3 min delay will
Automatic blowing direction
not be entered. However, the set
Yes
room temperature and the blowing
Filter sign
Yes
velocity will be according to the
Wireless mode
Cooling/Heating
remote control signal. The same
applies for switching from "Heating"
to "Automatic" heating.
Table 2 Sensor operation values
6.
In case of switching from "Sensor
Item
dehumidification" operation to
Cooling, Sensor
16
17.6
"Cooling", as it is when the
thermostat is ON. 3 min delay will
ON temperature
dehumidification
24
25.6
not be entered. However, the set
Thermostat
(Thermostat relay)
32
33.6
room temperature and the blowing
operation
power relay
Heating
16
19.6
velocity will be according to the
(°C)
24
27.6
remote control signal.
32
35.6
The same applies for switching
Differential (°C)
0.33
from
"Cooling" to "Sensor dehumidifica-
tion". The same also applies for
"Automatic" sensor dehumidifica-
Low-temperature
(T1)
ON (°C)
1.0
tion, cooling "Sensor dehumidifica-
defrosting
Reset (°C)
12.0
tion", "Cooling".
Preheating
Reset (°C)
17.0
ON (°C)
15.0
7.
The filter sign lights after operation
of the indoor fan for 200 hours. The
time is cleared when power switch
set to OFF and ON again.
Pd cut 1
(T3)
ON (°C)
56.0
(T4)
Reset (°C)
52.0
Pd cut 2
(T6)
ON (°C)
66.0
(T7)
Reset (°C)
57.0
(T5) Fan Relay H [ Original (°C)
58.0
Pd cut 3
(T8)
ON (°C)
62.0
(T9)
Reset (°C)
57.0
8.
After entry into trouble mode (when
the indication lamp is flashing), the
rapid feed mode can not be
changed.
H in the same way as
9.
When
operation
by
nice
temperature
reservation
is
executed during sleep operation,
normal operation will be continued,
and the advance time becomes the
temperature difference between the
set temperature without sleep shift
and the room temperature.
10.
The 50 minutes of defrosting
prohibition are counted from
Thermostat ON after start/stop
switch ON. When the thermostat
is OFF at the time of start/stop
switch ON, the 60 minutes will be
counted from the time of thermostat
ON. The initial OFF time is not
counted. Counting starts when the
thermostat becomes ON, and the
count then continues even if the
"Automatic"
heating
thermostat becomes OFF.
11.
In case of switching from "Heating"
the reversing valve is held for 3
minutes.
12.
The defrosting signal is not
accepted with overload input, and
the operation becomes as shown
below when the overload input
disappears.
(1)
When
previously
the
defrosting signal existed
without overload input,
defrosting
will
start
immediately.
(2)
In cases other than the
above, defrosting will be
executed with a defrosting
signal in the condition
without overload input.
– 43 –