CONSTRUCTION AND DIMENSIONAL DIAGRAM

MODEL RAS-30CH6/RAC-30CH6
About
380
Viewed from back
(bottom direction pipe
lead-out)
Note:
1. Servicing space of 100mm or more is required on the left and right sides of the indoor unit and also 50mm or
more space is required above the unit
2. Insulated pipes should be used for both the narrow and wide dia. pipes.
3. Piping length is within 30m
4. Height different of the piping between the indoor unit and the outdoor unit should be within 10m.
5. Power supply cord length is about 2m
6. Connecting cable 2.5mm dia. x 3 (AB Line), 1.6mm dia. x 2 (CD Line) is used for the connection.
0301E (30CH6) pg 30-34
Indoor Unit
L
N
A
B
C
D
Line
cord
30
Notes:
1. Service space (free space needed for
servicing) is 200mm on the right, 100mm
on the left and 50mm on top.
2. The wide and narrow pipes must be
thermally insulated.
Outdoor Unit
Connecting
RED
D
Cord
BRN
C
ø1.6 or ø2.0
WHT
B
BLK
A
ø2.0
– 30 –
16/12/05, 2:40 PM
Unit : mm
56
17.5
Wireless remote controller
When piping is drawn
horizontally, exchange
the drain hose for the
drain cap.