MAIN PARTS COMPONENT

THERMOSTAT (Room Temperature Thermistor)
Thermostat Specifications
MODEL
THERMOSTAT MODEL
OPERATION
TEMPERATURE °C
FAN MOTOR
Fan Motor Specifications
MODEL
PHASE
RATED VOLTAGE
RATED FREQUENCY
OUTPUT
POLE NUMBER
CONNECTION
RESISTANCE VALUE
0301E (30CH6) pg 30-34
INDICATION
16
INDICATION
24
INDICATION
32
100-322V
0-6.5V
20°C
( )
75°C
32
COOL
ON
17.6 (63.7)
OFF
17.3 (63.1)
ON
25.6 (78.1)
OFF
25.3 (77.5)
ON
33.6 (92.5)
OFF
33.3 (91.9)
RAS-30CH6
– – – – –
DC100V-322V
– – – – –
30 W
– – – – –
RED
BLK
0V
WHT
M
15V
YEL
BLU
F.G
– – – – –
– – – – –
– 32 –
16/12/05, 2:40 PM
RAS-30CH6
IC
HEAT
19.6 (67.3)
19.3 (66.7)
27.6 (81.7)
27.3 (81.1)
35.6 (96.1)
35.3 (95.5)
RAC-30CH6
SINGLE
220-240V
50 Hz
80 W
6
RED
INTERNAL
THERMAL FUSE
RM
BLACK
RA
CAPACITOR
GRAY
RM = 55.2
RA = 40.1
RM = 68.1
RA = 49.5