Advertisement

PL Lite Series
User Manual
Shenzhen Absen Optoelectronic Co.,Ltd.

Advertisement

Table of Contents
loading

Summary of Contents for Absen PL Lite Series

  • Page 1 PL Lite Series User Manual Shenzhen Absen Optoelectronic Co.,Ltd.
  • Page 2: Table Of Contents

    5.2.2 Power Box Maintenance ......................- 25 - 5.2.3 Receiving card and HUB Board Maintenance ..............- 26 - 5.2.4 Flight Case ..........................- 27 - 6.Common faults and troubleshooting ......................- 28 - - 2 - PL Lite Series User Manual...
  • Page 3: Safety Information

    Follow safety instructions in this manual and on the product. If you have any questions, please seek help from Absen. Beware of Electric Shock! • To prevent electric shock the device must be properly grounded during installation, Do not ignore using the grounding plug, or else there is a risk of electric shock.
  • Page 4 • Any component that has a recycling bin label can be recycled. • For more information on collecting, reusing and recycling, please contact the local or regional waste management unit. • Please contact us directly for detailed environmental performance information. - 4 - PL Lite Series User Manual...
  • Page 5 To prevent damage to LED lamps, do not touch when the device is running or switched off. WARNING: The manufacturer shall not bear any responsibility for any incorrect, inappropriate, irresponsible or unsafe system installation. PL Lite Series User Manual - 5 -...
  • Page 6: 1.Product Introduction

    PL lite series have a full range of pixel pitch for stage display including 2.5, 2.9, 3.9 and 4.8mm, among which P3.9 & P4.8 have outdoor version. There are also curve version and cube version (PL2.5 Lite/PL2.9 Lite/PL3.9 Lite/PL3.9W Lite only).
  • Page 7: Product Main Features

    Product Main Features • PL lite series include curve version, which can provide an excellent effect of screen splicing. PL2.5 lite/PL2.9 lite/PL3.9 lite/PL3.9W lite also have creating cube version, which can provide a variety of creative splicing solutions. • The whole PL lite series supports 3840Hz refresh rate, bringing outstanding effect on camera, which significantly improves customers’...
  • Page 8: Product Specifications

    Working Humidity (RH) 10%~90% Ingress Protection IP40/IP21 Product Life (hrs) 100000 Leasing Panel Installation Method Rigging/Stacking Product Maximum number of hoisted Installation cabinets Remark: Power consumption tolerance: ±15%, according to the actual situation. - 8 - PL Lite Series User Manual...
  • Page 9 Working Humidity (RH) 10%~90% Ingress Protection IP65/IP54 Product Life (hrs) 100000 Panel Installation Method Rigging/Stacking Leasing Product Maximum number of hoisted Installation cabinets Remark: Power consumption tolerance: ±15%, according to the actual situation. PL Lite Series User Manual - 9 -...
  • Page 10 Ingress Protection IP40/IP21 IP40/IP21 IP40/IP21 IP65/IP54 Product Life (hrs) 100000 Leasing Panel Installation Method Rigging/stacking Product Maximum number of hoisted Installation cabinets Remark: Power consumption tolerance: ±15%, according to the actual situation. - 10 - PL Lite Series User Manual...
  • Page 11: Cabinet Dimension Figure

    (mm) Cabinet dimension figure Unit: mm 1000 PL Lite Series User Manual - 11 -...
  • Page 12: 2.Product Components

    2.Product Components 2.1 Cabinet Introduction Locking system Curved lock Locking system Module Locking system Power box Locking system Curved lock Locking system module Locking system Power box - 12 - PL Lite Series User Manual...
  • Page 13: 3.Product Installation

    The product is suitable for various forms of installation, including rigging and stacking installation. Use the locking system to lock the cabinets during installation. The curved lock can support radian connection from -7.5 ° to +10°. Standard locking: Lock up and down PL Lite Series User Manual - 13 -...
  • Page 14: Hanging Installation

    Creating 90° Corner 3.1 Hanging Installation 3.1.1 Hanging bar Illustration Used for rigging installation, including single, double hanging bar and 90 degree hanging bar. - 14 - PL Lite Series User Manual...
  • Page 15: Hanging Bar Installation

    5. Tighten the safe lock from left to right 6. Tighten the second cabinet, as described above Note: For detailed installation steps, see the product installation video STEP Graphic 1, Fix the Hanging Bar on the Truss PL Lite Series User Manual - 15 -...
  • Page 16 3, Press the locking plate on the hanging beam 4, Insert the safe lock on the cabinet up 5, Tighten the safe lock from left to right 6, Align the left and right cabinet mounting holes - 16 - PL Lite Series User Manual...
  • Page 17 7, Lock the left and right cabinet, 8, Install other cabinets as described above 9, Install the module Single hanging bar Double hanging bar PL Lite Series User Manual - 17 -...
  • Page 18: Stacking Installation

    2. For the installation method of the cabinet, please refer to the installation above. 4.Product Cabling 4.1Preparation Before Cabling Please check carefully if the connection of power and signal circuit is correct before - 18 - PL Lite Series User Manual...
  • Page 19: Power Supply And Signal Cable Wiring

    AC contactor, circuit breaker (air switch), arrester (optional), timer, function card, time delay unit, voltage indicator, current indicator, Thermal relay, e.tc Power capacity: Absen mainly has 15KW, 30KW, 60KW, 90KW, 120KW, 150KW, 180KW distribution boxes. Control mode: intelligent distribution box, ordinary distribution box.
  • Page 20 Less Than 3.5 mA, Less Than 3.5 mA, Leakage Current @ 264Vac input @ 240Vac input Normal output power 180W 250W Electrical Characteristics of Output Output Voltage +4.5V +4.5V Rated current Cable connection - 20 - PL Lite Series User Manual...
  • Page 21 Please calculate the resolution according to each box pixel and connect the signal line according to the load range of the sending card. No more than 655360 pixels can be loaded on each network port. PL Lite Series User Manual - 21 -...
  • Page 22: Standard Cable Wiring

    4.2.2 Standard Cable Wiring 100V-120V 220V-240V Signal Cable Distribution Box - 22 - PL Lite Series User Manual...
  • Page 23: 5.Maintenance

    Measuring power lines multimeter and distribution boxes List Small Phillips Installing and removing screwdriver mask Spirit level Measuring structure Measuring installation Laser spirit level position Measuring distance of Band tape installation hole PL Lite Series User Manual - 23 -...
  • Page 24: Maintenance Instructions

    5.2 Maintenance Instructions 5.2.1 Module Maintenance The module of PL Lite series support front or rear maintenance. The maintenance mode of modules of PL XL cabinet and cube cabinet are similar to that of 500×500 cabinet, which will not be repeated here.
  • Page 25: Power Box Maintenance

    Unscrew the loose screw of the power box and remove it for maintenance. (screw position is shown in the circle) Attention: It is necessary to cut off power supply of cabinets during the maintenance of the power box to avoid electric shock. PL Lite Series User Manual - 25 -...
  • Page 26: Receiving Card And Hub Board Maintenance

    Maintenance for the HUB Board (Rear) : For the maintenance of the HUB board, please refer to the maintenance method of the receiving card. Please remove the fixing screw when maintenance (marked with a red circle). - 26 - PL Lite Series User Manual...
  • Page 27: Flight Case

    Flight cases are optimised to fit in vehicles for low cost transport. Fully stackable to save space. PL Lite series flight case has 6in1 and 4in1. 6 in 1 is suitable for the 500×500 cabinet and 4 in 1 is designed for the 500×1000 cabinet.
  • Page 28: 6.Common Faults And Troubleshooting

    8. Replace the computer; 1. Check whether the power plug of the receiving card is well Screen show s crambled imag inserted; 2. Check whether the power cable of the receiving card is burnt - 28 - PL Lite Series User Manual...
  • Page 29 2. Check the output resolution of the video processor; display 3. Check the output window of the video processor; All rights reserved by Shenzhen Absen Optoelectronic Co., Ltd. Shenzhen Absen Optoelectronic Co., Ltd. reserves the rights to modify contents without any further notice. PL Lite Series User Manual...
  • Page 30 Shenzhen Absen Optoelectronic Co., Ltd. 18-20F Building 3A, Cloud Park, Bantian, Longgang District, Shenzhen 518129, P.R.China T: +86-755-89747399 absen@absen.com W: www. absen.com - 30 - PL Lite Series User Manual...