  • Page 1 PL3.9W User Manual STEP Simple Operation Panel Weight Cooling System Fast Assembly High Brightness Front Servicing High Refresh...
  • Page 2 Table of content Safety Information Product Introduction About POLARIS Product Specifications Basic Wiring Overview for Hanging Installation Locking System Product Assembly Hanging Bar/Rigging Bar Service and Maintenance Flight Cases...
  • Page 3 This product may result in serious injury or death due to fire hazard, electric shock or on dropping. Please read this manual carefully before installing, powering up, operating and maintenance of this product. Follow safety instructions in this manual and on the product. If you have any questions, please seek help from Absen.
  • Page 4 Beware of Electric Shock!  To prevent electric shock the device must be properly grounded during installation. Do not ignore using the grounding plug, or else there is a risk of electric shock.  During a lightning storm, please disconnect the device’s power supply, or provide other suitable lightning protection.
  • Page 5 Beware of Injury!  Warning: Wear a helmet to avoid injury.  Ensure any structures used to support, fix and connect the equipment, can withstand at least 10 times the weight of all the equipment.  When stacking products, please hold products firmly to prevent tipping or falling.
  • Page 6 01 Product Introduction 1. Product PL series display is a product specially designed for stage rental use. It is mainly used in rental applications for large concerts, shows, auto shows, business activities, etc., as a medium for video broadcast, information release, and so on. The product has has different pixel pitch, and is high-definition display for indoor rental use.
  • Page 7 2. Basic Wiring Overview for Hanging Installation and Stacking Installation Notes: 1、Hanging bars can load a max height of 20 panels of PL3.9W and 10 panels of PL3.9W XL, and the stacking system can load a max of 10 panels PL3.9W and 5 panels PL3.9W XL.
  • Page 8 02 Locking System 2.1 Standard Locking Auto-Lock and Auto-Eject systems Auto-locking Vertical Lock System Auto-connection For Fast and Easy 1 Man Installation With Ultimate Safty And Pixel Protection. Auto-ejection Side Lock System Enables Super Fast, East And Convenient Disconnection Of Panels. ...
  • Page 9 2.1 Horizontal Locking Procedures Inner and outer curve lock systems Innovative integrated repositionable curve connection block system maintains the highest level of alignment accuracy in both flat of curve configuration. Curve connection blocks are available to support any increment of curve from -7.5 convex to +10 concave giving users unlimited design flexibility and control.
  • Page 10 03 Product Assembly 3.1 Procedure Haring...
  • Page 11 Hanging Installation Fix the Hanging Bar on the Truss Turn the adjustment screw to make the clamps close. The hanging bar should be directly affixed to the truss. Connect and assemble tiles.
  • Page 12 3.2 haring bar 0.5m haring bar 1m haring bar...
  • Page 13 04 Service and Maintenance Module Front Maintenance 1.Take off the failure module Step1:Attach the vacuum maintenance tool to the module and press the maintenance tool switch before vacuum for 5 seconds. Pull it vertically and pull the module off the panel. Step 2:Unload the module safety rope and remove the failure module...
  • Page 14 2、Replace a good module Step1: The module is ready to rotate the module safety rope screw on the module and lock it tightly. Step2:After the module safety rope lock is used, the module is adsorbed by the vacuum front maintenance tool, and the die is assembled back to the panel from the vertical direction.
  • Page 15 Module Rear Maintenance 1、Take off the failure module Step1: The handle of the handheld module pushes the module vertically and pushes the module out of the panel. Step2: Remove the module safety rope and tilt the module 45 degrees from the panel to remove the module.;...
  • Page 16 Easy Maintenance for Power Box Step1:Turn the power box safety knob, push the switch upwards and turn on the power box. Step2:After removing 2 pcs DATA cabels and 1 2P cabel , remove the power box.
  • Page 17 Maintenance for receiver card Step1: Remove the power box from the box and screw down the screws of 4 fixed receiving cards with a screwdriver. Step2:Remove the fault receiving card, install the new receiving card and lock it with screws to complete the replacement of the receiving card.
  • Page 18 Maintenance for the HUB card Step1:After taking off the power box, screw the 10 screws of the fixed HUB card with a screwdriver and remove the HUB card; Step2:Replace the new HUB card and install the receiving card.;...
  • Page 19 06 Flight case LED panels stored horizontally to prevent SMD damage. Flight cases are optimised to fit in vehicles for low cost transport. Fully stackable to save space. 6 in 1 design.
  • Page 20 All rights reserved by Shenzhen Absen Optoelectronic Co., Ltd. Shenzhen Absen Optoelectronic Co., Ltd. reserves the rights to modify contents without any further notice. Shenzhen Absen Optoelectronic Co., Ltd. 18-20F Building 3A, Cloud Park, Bantian, Longgang District, Shenzhen 518129, P.R.China T: +86-755-89747399 absen@absen.com...