Perle IDS-306 Hardware Installation Manual

Perle IDS-306 Hardware Installation Manual

Managed industrial
Hide thumbs Also See for IDS-306:

Advertisement

Quick Links

IDS-306 Hardware Installation Guide
Managed Industrial Ethernet Switches
Updated: October 2019
Revision 1.1
www.perle.com
Document Part#: 5500375-10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDS-306 and is the answer not in the manual?

Questions and answers

Summary of Contents for Perle IDS-306

  • Page 1 IDS-306 Hardware Installation Guide Managed Industrial Ethernet Switches Updated: October 2019 Revision 1.1 www.perle.com Document Part#: 5500375-10...
  • Page 2 Modifications to this product not authorized by Perle could void the FCC approval and negate your authority to operate the product. Perle reserves the right to make changes without further notice, to any products to improve reliability, function, or design.
  • Page 3: Table Of Contents

    Table of Contents Preface ......................2 Overview .
  • Page 4: Preface

    This document describes the hardware and physical characteristics of the Perle IDS switch. It covers hardware features as well as installation and operation of the switch. This document does not cover how to configure your Perle IDS switch. Information to configure your Perle IDS switch can be found in the Perle IDS User’s Guide Package Contents •...
  • Page 5: Overview

    Port Status Indicators The table below gives a brief overview of the models covered in this guide. For more details and for the most up-to-date list of models, please refer to the product pages at www.perle.com. Standard Models Port 1-5...
  • Page 6: Switch Model View

    Switch Model View IDS-306 IDS-306 Hardware Installation Guide...
  • Page 7: Led Indicators

    Alarms configured, but no alarms detected Alarm condition detected Red - solid Red - blinking Alarm condition detected and Alarm Relay activated BC (Backup Coupling) State Description Backup Coupling not enabled Green - solid Backup Coupling Link enabled IDS-306 Hardware Installation Guide...
  • Page 8 Ring Master Active, redundant port unblocked - indicates a break in the Ring 6 (Port 6 - SFP Link/Activity status) State Description Link Down Green - flashing Link and activity Green - blinking slowly Port in error disable or suspended state IDS-306 Hardware Installation Guide...
  • Page 9: Ports

    CLI command set. This port has an RJ-45 connector. See RJ-45-Console Port Pin- outs for pinouts. 100/1000 Mb/s SFP Slots The SFP slots can accommodate industry standard SFP’s from Perle or other suppliers. These SFP’s can be 100 or 1000 Mb/s or can be SGMII models including 1000Base-T Copper SFP’s. Power Connector The power input connector has provisions for dual inputs.
  • Page 10: Port Status Indicators

    Port Link / Speed (Green and Yellow LEDs) State Description Green 1000 Mbps Green / Yellow 100 Mbps Yellow 10 Mbps On solid Port Link Random blinking Port Link and Activity Slow blinking Error disabled Rapid blinking Port in Fast Setup Mode IDS-306 Hardware Installation Guide...
  • Page 11: Installation

    Ensure power has been removed at the source of the alarm circuit prior to proceeding with the connections to the alarm relay. Warning: Ensure that voltage and current supplied by the alarm circuits are within the stated Alarm Relay specifications. IDS-306 Hardware Installation Guide...
  • Page 12: Terminal Block-Power Connectors

    Warning: In case of malfunction or damage, no attempts at repair should be made. Do not dismantle the product. All repairs need to be made by a qualified Perle representative. Warning: Explosion hazard. Do not remove or replace lamps, fuses or plug-in modules (as applicable) unless power has been disconnected or the area is free of ignitable concentrations.
  • Page 13: Connecting The Console Port

    1 Connect an RJ45 cable to the IDS switch console port (RJ45) and the other end of the cable to a COM port on your PC. 2 Choose Start > Control Panel > Systems or equivalent on the Windows Operating System you are using. IDS-306 Hardware Installation Guide...
  • Page 14: Connecting Destination Ports

    SFP Connections Inserting the SFPs SFP modules are inserted in the SFP slots on the front of the IDS switch. 1 Align the SFP module in front of the slot to establish alignment. IDS-306 Hardware Installation Guide...
  • Page 15 SFP and pull towards you. Warning: In hazardous location installations, failure to remove the power from the source prior to removing the SFP modules from their slots could cause an electrical arc resulting in a possible explo- sion. IDS-306 Hardware Installation Guide...
  • Page 16: Resetting The Switch

    All LEDs will be off after 8 seconds. Reset to Factory Default Configuration The IDS-306 can be reset to the Factory default configuration. When this is done, all configuration, user IDs, passwords and security certificates are deleted. The start-up and backup software are unaffected.
  • Page 17: Booting The Switch

    When the switch is not in factory default the "Fast Setup Mode" sequence will activate Password recovery. Note: The password recovery feature can be disabled in the software. Behavior On solid - during reset process Off - to indicate that reset has completed IDS-306 Hardware Installation Guide...
  • Page 18: Configuring The Ids Switch

    Command Line Reference Guide for more information. Web Device Manager The Perle Web Device Manager is an embedded Web based application that provides an easy to use browser interface for managing the switch. This interface provides the ability to configure and manage the switch.
  • Page 19: Appendix A - Technical Specifications

    Appendix A - Technical Specifications This appendix provides the technical specification for the IDS-306(-XT) switches. Specifications Dual input terminal block 9.6 to 60 VDC SELV, limited-energy per 61010-1 cl.9.4 Models Rated Voltage Max. Rated Alarm Relay Output (CLASS 2) Current IDS - 306(-XT) 9.6 Vdc...
  • Page 20 60°C (140°F). However, the IDS switch can function in the environmental conditions listed above. Contacting Technical Support Contact information for the Perle Technical Assistance Center (PTAC) can be found at the link below. A Technical Support Query may be made via this webpage. www.perle.com/support_services/support_request.shtml Warranty / Registration This product is covered by the Perle Ethernet Switches Warranty.
  • Page 21: Appendix B - Labels

    Appendix B - Labels IDS-306 IDS-306-XT IDS-306 Hardware Installation Guide...
  • Page 22: Appendix C - Mechanical Drawings

    Appendix C - Mechanical Drawings 5-port RJ-45 IDS-306 Hardware Installation Guide...
  • Page 23: Appendix D - Ids Din Rail And Wall Mounting

    If you have purchased the optional wall mounting kit then proceed as below: 1 Remove the DIN rail clip from the rear panel on the IDS switch. 2 Attach the wall mount plates to the IDS switch as shown below using the screws provided in the kit. IDS-306 Hardware Installation Guide...
  • Page 24 6 Pull the IDS switch down to lock the IDS switch to the wall mount. 7 Tighten the four screws securely to the wall. Note: for best results use screws with the following attributes Head diameter .5 - .6 mm Shaft diameter 3 -3.5 mm IDS-306 Hardware Installation Guide...
  • Page 25: Appendix E - Ids Maintenance

    Do not use solvents or cleaning agents on this unit • Keep vent holes clear of debris • If case gets dirty wipe with a dry cloth • Ensure all cables are in good working condition • Replace any frayed cables or cables without clips IDS-306 Hardware Installation Guide...
  • Page 26: Appendix F - Cables And Connectors

    - 0.33mm • Straight through or Ethernet Crossover cable Note: An optional cable adapter is available to provide RJ45 to DB9 conversion: Perle’s optional RJ45 to DB9-F crossover adapter model DB0020C enables a straight through Ethernet cable to connect the RJ45 console port to a PC serial port.
  • Page 27 Installing and removing SFP transceiver modules can shorten their useful life. Do not install or remove transceiver modules more than is necessary. Warning: This is a Class 1 Laser/LED product. To avoid causing serious damage to your eyes, do not stare directly into the Laser Beam. IDS-306 Hardware Installation Guide...

This manual is also suitable for:

Ids-306-xt

Table of Contents