Perle IDS-710HP Hardware Installation Manual

Perle IDS-710HP Hardware Installation Manual

Poe managed industrial ethernet switches
Hide thumbs Also See for IDS-710HP:

Advertisement

Quick Links

IDS-710HP Hardware Installation Guide
PoE Managed Industrial Ethernet Switches
Updated: April 2020
Version: A.07.04.2020
Document Part# 5500455-10
www.perle.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDS-710HP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Perle IDS-710HP

  • Page 1 IDS-710HP Hardware Installation Guide PoE Managed Industrial Ethernet Switches Updated: April 2020 Version: A.07.04.2020 Document Part# 5500455-10 www.perle.com...
  • Page 2 Modifications to this product not authorized by Perle could void the FCC approval and negate your authority to operate the product. Perle Systems Limited reserves the right to make changes without further notice, to any products to improve reliability, function, or design.
  • Page 3: Table Of Contents

    Table of Contents Preface ......................2 Overview .
  • Page 4: Preface

    710HP Switch. It covers hardware features as well as installation and operation of the switch. This document does not cover how to configure your Perle IDS-710HP Switch. Information to configure your Perle IDS-710HP can be found in the IDS PoE Switches User Guide.
  • Page 5: Overview

    The table below gives a brief overview of the models covered in this guide. For more details and for the most up-to-date list of models, please refer to the product pages at: www.perle.com 10/100/1000 Base-T Fixed SFP Standard Models Software Set Temp Ethernet Ports Port PoE Enabled IDS-710HP Standard IDS-710HP-XT Industrial IDS-710HP Hardware Installation Guide...
  • Page 6: Switch Models Views

    Switch Models Views IDS-710HP (including XT models) 1 – Reset / FS (Fast Setup) 6 – SFP slots 2 – Status LEDs 7 – 10/100/1000Base-T Ethernet Ports with PoE/PoE+/PoE++ capability 3 – Terminal Block for Digital Input and 8 – Terminal Block for Power 1, 2 Relay 4 –...
  • Page 7 PoE+/PoE++ PD devices. SFP Slots The SFP slots can accommodate industry standard SFPs from Perle or other suppliers. These SFPs can be fiber or copper. The fiber SFP run at a speed of 1000 or 2500 Mbps. The copper SFP are SGMII based and can support speeds of 10/100/1000 Mbps.
  • Page 8: Port Status Indicators

    LED 1: Green LED 2: Green 100 Mbps LED 1: Off LED 2: Green 10 Mbps On solid Port Link Random blinking Port Link and Activity Slow blinking Error disabled Rapid blinking Port in Fast Setup Mode IDS-710HP Hardware Installation Guide...
  • Page 9 SFP Status LEDs State Description Green Fiber link established Green flashing Link/activity No Link Each SFP has a corresponding LED to indicate the current state of the fiber link. IDS-710HP Hardware Installation Guide...
  • Page 10: Terminal Block Connectors

    P2 (+/-) — Power Input 2. Either P1 or P2 can power the unit. When both are connected, one will act as a backup. IN(+/-) — Digital Input. Dry Contact. Relay — Normally Open (NO) relay. IDS-710HP Hardware Installation Guide...
  • Page 11: Installation

    Wiring with suitable temperature ratings must be used. Refer to specification section for details. Use copper wire only if the terminal is only for connection to copper wire. 1. Ensure the power source is off prior to connection. 2. Strip both (12-20AWG) wires 7-8 mm(5/16th). IDS-710HP Hardware Installation Guide...
  • Page 12: Wiring The Relay Alarm

    3. Loosen the terminal block screws and connect wires into the terminals. 4. Tighten terminal screws. Ensure the wires are securely fastened. 5. Re-insert the Terminal block connector if removed. 6. Turn on power source. Terminal Block Connectors. IDS-710HP Hardware Installation Guide...
  • Page 13: Connecting The Console Port

    • 8 data bits • 1 stop bit • No parity • None (flow control) 6. The PC will display the bootloader sequence. 7. Press Enter to display the setup prompt when the booting of the IDS is completed. IDS-710HP Hardware Installation Guide...
  • Page 14: Connecting Data Ports

    1. Align the SFP module in front of the slot to establish alignment. 2. Insert the module and push inwards with your thumb until you hear a click. Do not force the SFP module in. SFP modules are keyed so you can only insert them one way. IDS-710HP Hardware Installation Guide...
  • Page 15: Resetting The Switch

    SFP and pull towards you. Resetting the Switch The Reset/Fast Setup button is located near the bottom of the switch. A small tool such as a paper clip is needed to access the recessed button. IDS-710HP Hardware Installation Guide...
  • Page 16 The LEDs will behave according to the table below. Behavior Yellow during the booting process. Once the system software has been loaded, the PWR LED will reflect the status of the power inputs. Green blinking — Boot process underway. IDS-710HP Hardware Installation Guide...
  • Page 17 When the switch is not in factory default, the "Fast Setup Mode" sequence will activate Password recovery. Note: The password recovery feature can be disabled in the software. Behavior On solid - during reset process Off - to indicate that reset has completed IDS-710HP Hardware Installation Guide...
  • Page 18: Configuring The Ids Switch

    Web Device Manager The Perle Web Device Manager is an embedded Web based application that provides an easy to use browser interface for managing the switch. This interface provides the ability to configure and manage the switch. This is accessible through any standard desktop web browser.
  • Page 19: Appendix A - Technical Specifications

    Appendix A - Technical Specifications This appendix provides the technical specification for the IDS-710HP(-XT) switches. Technical Specification Power Power Connector • 4-Pin Removable Terminal Block • Grounding screw on metal chassis • Dual Power Input Dual Power Input • 54 VDC nominal 52-57 VDC (PoE++ IEEE 803.2bt Type 4), 9A Max.
  • Page 20 SFP slot • 2 SFP slots provided • Supports 1000Base-X and 2500Base-X SFP mod- ules supplied by Perle, Cisco or other manufactur- ers of MSA compliant SFPs SFPs supporting SGMII protocol are also supported (example 1000Base-T) Console port •...
  • Page 21 IEC/EN 61000-4-11 IEC/EN 61000-6-2 (General Immunity in Industrial Environments) Laser Safety Class 1 Laser safety requirements for those models with fixed fiber transceiver modules EN 60825-1:2007 FDA/CDRH 21 CFR1040.10 and 21 CFR1040.11 Environmental Reach RoHS WEEE Compliant IDS-710HP Hardware Installation Guide...
  • Page 22 Contact information for the Perle Technical Assistance Center (PTAC) can be found at the link below. www.perle.com/support_services/support_request.shtml Warranty / Registration This product is covered by the Perle Ethernet Switches Warranty. Details can be found at: https://www.perle.com/support_services/warranty.shtml IDS-710HP Hardware Installation Guide...
  • Page 23: Appendix B - Sample Labels

    Appendix B - Sample Labels IDS-710HP Hardware Installation Guide...
  • Page 24: Appendix C - Mechanical Drawings

    Appendix C - Mechanical Drawings IDS-710HP Hardware Installation Guide...
  • Page 25: Appendix D - Din Rail And Wall Mounting

    2. Insert a flat blade screwdriver into the slot and twist the base to release the clip. Alter- natively a downward force on the clip will release the clip. 3. When the clip is released, pull the bottom of the switch out slightly and remove the switch from the DIN rail. IDS-710HP Hardware Installation Guide...
  • Page 26 6. Pull the IDS switch down to lock the IDS switch to the wall mount. 7. Tighten the four screws securely to the wall. Note: for best results use screws with the following attributes Head diameter .5 - .6 mm Shaft diameter 3 -3.5 mm IDS-710HP Hardware Installation Guide...
  • Page 27: Appendix E - Ids Maintenance

    Do not use solvents or cleaning agents on this unit • Keep vent holes clear of debris • If case gets dirty wipe with a dry cloth • Ensure all cables are in good working condition • Replace any frayed cables or cables without clips IDS-710HP Hardware Installation Guide...
  • Page 28: Appendix F - Cables And Connectors

    Straight through or Ethernet Crossover cable Note: An optional cable adapter is available to provide RJ45 to DB9 conversion: Perle’s optional RJ45 to DB9-F cross- over adapter model DB0020C enables a straight through Ethernet cable to connect the RJ45 console port to a PC serial port.
  • Page 29 For PoE++ devices up to 60 watts per port • IEEE 802bt (Type 4) standards • For PoE++ devices up to 100 watts per port Connect the copper cables from each TP port(RJ45) on the IDS-710HP switch to compliant Powered Devices (PDs). IDS-710HP Hardware Installation Guide...

This manual is also suitable for:

Ids-710hp-xt

Table of Contents