Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip (only
for cooling and heating unit).
Note:
• After tighten the screw, pull the power cord slightly to check it it is firm.
• Never cut the power connection wire to prolong or shorten the distance.
Step six: neaten the pipes
1. The pipes should be placed along
the wall, bent reasonably and hidden
possibly. Min. semidiameter of
bending the pipe is 10cm.
2. If the outdoor unit is higher
than the wall hole, you must set a
U-shaped curve in the pipe before
pipe goes into the room, in order
to prevent rain from getting into the
room.
Outdoor Condensate Drainage (only for Heat pump unit)
During heating operation, the con-
densate and defrosting water should
be drained out reliably through the
drain hose. Install the outdoor drain
connector in a Φ25 hole or Φ42
hole on the base plate and attach
the drain hose to the connector so
that the waste water formed in the
outdoor unit can be drained out.
The hole diameter 25 or 42 must be
plugged. Whether to plug other holes
will be determined by the dealers to
actual conditions.