  • Page 1 OWNER’S MANUAL Split Air Conditioner IAPH301A / OAPH301A IAPH361A / OAPH361A CONFORMS TO UL STD. 1995 Thank you for choosing our product. CERTIFIED TO CSA STD. C22.2 NO. 236 For proper operation, please read and keep this manual carefully. If you have lost the Owner’s Manual, please visit: www.mirageappliances.us...
  • Page 2: Explanation Of Symbols

    Explanation of Symbols Indicates a hazardous situation that, if not avoided, will result in DANGER death or serious injury. Indicates a hazardous situation that, if not avoided, could result in WARNING death or serious injury. Indicates a hazardous situation that, if not avoided, may result in CAUTION minor or moderate injury.
  • Page 3: Table Of Contents

    Content Operation Notices Precautions ......................Parts name ....................... Screen Operation Guide Buttons on remote controller ................Introduction for icons on display screen ............Introduction for buttons on remote controller ............ Function introduction for combination buttons ..........Operation guide ....................Replacement of batteries in remote controller ..........Emergency operation ..................
  • Page 4: Precautions

    Precautions WARNING Operation and Maintenance • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory ormental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 5 Precautions WARNING • Do not block air outlet or air inlet. It may cause malfunction. • Do not spill water on the remote controller, otherwise the remote controller may be broken. • When below phenomenon occurs, please turn off air conditioner and disconnect power immediately, and then contact the dealer or qualified professionals for service.
  • Page 6 Precautions WARNING Attachment • Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. • Must follow the electric safety regulations when installing the unit. • According to the local safety regulations, use qualified power supply circuit and circuit break. •...
  • Page 7 Precautions WARNING • Do not put through the power before finishing installation. • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. • The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  • Page 8 Precautions WARNING • For the air conditioner with plug, the plug should be reachable after finishing installation. • For the air conditioner without plug, an circuit break must be installed in the line. • If you need to relocate the air conditioner to another place, only the qualified person can perform the work.
  • Page 9: Parts Name

    Parts Name Indoor Unit air inlet panel aux.button horizontal louver air outlet remote control Outdoor Unit air inlet Connection wire air outlet NOTICE Actual product may be different from above graphics, please refer to actual products.
  • Page 10: Buttons On Remote Controller

    Buttons on remote controller ON/OFF button MODE button FAN button SWING button TURBO button SLEEP button TEMP button I FEEL button LIGHT button CLOCK button TIMER ON / TIMER OFF button Introduction for icons on display screen Set fan speed I feel Send signal Operation mode...
  • Page 11: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller screen Note: • This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn’t have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 12 Introduction for buttons on remote controller screen When selecting heating mode, the air conditioner operates under heat mode. Heat indicator on indoor unit is ON. Press “▲” or “▼“ button to adjust set temperature. Press “FAN” button to adjust fan speed. Press “SWING” button to adjust fan blowing angle.
  • Page 13 Introduction for buttons on remote controller screen TURBO button Under COOL or HEAT mode, press this button to turn to quick COOL or quick HEAT mode. “ “ icon is displayed on remote controller. Press this button again to exit turbo function and “ “...
  • Page 14 Introduction for buttons on remote controller screen • It’s defaulted to display set temperature when turning on the unit.There is no display in the remote controller. • Only for the models whose indoor unit has dual-8 display. • When selecting displaying of indoor or outdoor ambient temperature, indoor temperature indicator displays corresponding temperature and automatically turn to display set temperature after thee or five seconds.
  • Page 15: Function Introduction For Combination Buttons

    Introduction for buttons on remote controller screen Press “TIMER ON” to confirm it. The word “ON” will stop blinking. “ “ icon resumes displaying. Cancel TIMER ON: Under the condition that TIMER ON is started up, press “TIMER ON” button to cancel it. •...
  • Page 16 Function introduction for combination buttons F heating function ° Under heating mode, press “TEMP” and “CLOCK” buttons simultaneously to start UP OR TURN OFF 46°F heating function. When this function is started up, “ “ and “46°F“ will be shown on remote controller, and the air conditioner keep the heating status at 46°F.
  • Page 17: Operation Guide

    Operation guide 1. After putting through the power, press “ON/OFF” button on remote control- ler to turn on the air conditioner. 2. Press “MODE” button to select your required mode: AUTO, COOL, DRY, FAN, HEAT. 3. Press “▲” or “▼” button to set your required temperature. (Temperature can’t be adjusted under auto mode).
  • Page 18: Emergency Operation

    Emergency operation If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: As shown in the fig. Open panel, press aux, button to turn on or turn off the air conditioner.
  • Page 19 Clean and Maintenance Clean Filter Clean filter Open panel • Use dust catcher or water to clean Pull out the panel to a certain the filter. angle as shown in the fig. • When the filter is very dirty, use the water (below 110°F) to clean it, and then put it in a shady and cool place...
  • Page 20 Clean and Maintenance NOTICE : Checking before use-season 1. Check whether air inlets and air outlets are blocked. 2. Check whether air switch, plug and socket are in good condition. 3. Check whether filter is clean. 4. Check whether mounting bracket for outdoor unit is damaged or corroded.
  • Page 21: Malfunction Analysis

    Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Phenomenon Check items Solution • Whether it’s interfered severely • Pull out the plug. Reinsert (such as static electricity, stable the plug after about 3min, and voltage)?
  • Page 22 Malfunction analysis Phenomenon Check items Solution • Power failure? • Wait until power recovery. • Is plug loose? • Reinsert the plug. Air conditioner • Air switch trips off or fuse is • Ask professional to replace air can’t operate burnt out? switch or fuse.
  • Page 23 Malfunction analysis Phenomenon Check items Solution Odours are emitted • Whether there’s odour • Eliminate the odour source. source, such as furniture and • Clean the filter. cigarette, etc. Air conditioner oper- • Whether there’s inter- • Disconnect power, put back ates abnormally ference, such as thunder, power, and then turn on the unit...
  • Page 24 Malfunction analysis Error Code • When air conditioner status is abnormal, temperature indicator on indoor unit will blink to display corresponding error code. Please refer to bellow list for identification of error code. Above indicator diagram is only for reference. Please refer to actual product for the actual indicator and position.
  • Page 25: Installation Dimension Diagram

    Installation dimension diagram Space to the wall At least 6’’ At least 6’’ Space to the wall Drainage pipe...
  • Page 26: Safety Precautions For Installing And Relocating The Unit

    Safety precautions for installing and relocating the unit To ensure safety, please be mindful of the following precautions. WARNING • When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant. Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury.
  • Page 27: Tools For Installation

    Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note: •...
  • Page 28: Requirements For Electric Connection

    Requirements for electric connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. 2. According to the local safety regulations, use qualified power supply circuit and air switch. 3. Make sure the power supply matches with the requirement of air conditioner.
  • Page 29: Installation Of Indoor Unit

    Installation of indoor unit Step one: choosing installation location Recommend the installation location to the client and then confirm it with the client. Step two: install wall-mounting frame 1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the level meter and then point out the screw fixing holes on the wall.
  • Page 30 Installation of indoor unit Indoor outdoor Note: • Pay attention to dust preven- tion and take relevant safety measures when opening the hole. • The plastic expansion 5-10 particles are not provided and should be bought locally. Step four: outlet pipe 2.
  • Page 31 Installation of indoor unit Hex nut diameter Tightening torque (lbft) Φ 1/4’’ Φ 3/8’’ Φ 1/2’’ Φ 5/8’’ Φ 3/4’’ 4. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and then wrap it with tape. Step six: install drain hose 1.
  • Page 32 Installation of indoor unit 2. Make the power connection wire go through the cable-cross hole at the back of indoor unit and then pull it out from the front side. 3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color;...
  • Page 33 Installation of indoor unit Step eight: bind up pipe drain hose connection pipe band 1. Bind up the connection pipe, power cord and drain hose with the band. indoor and indoor power cord outdoor power cord indoor unit pipe 3. Bind them evenly. 4.
  • Page 34: Installation Of Outdoor Unit

    Installation of outdoor unit Step one: fix the support of outdoor unit (select it according to the actual installation situation) 1. Select installation location according to the house structure. 2. Fix the support of outdoor unit on the selected location with expansion screws.
  • Page 35 Installation of outdoor unit Step four: connect indoor and outdoor pipes 1. Remove the screw on the right handle of outdoor unit and then 3.Tighten the union nut with remove the handle. torque wrench by referring to the sheet below. Hex nut diameter Tightening torque (lbft)
  • Page 36 Installation of outdoor unit 2. Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit). Note: • After tighten the screw, pull the power cord slightly to check it it is firm. •...
  • Page 37: Vacuum Pumping

    Vacuum pumping Use vacuum pump 1. Remove the valve caps on the liquid valve and gas valve and the nut of refrigerant charging port. 2. Connect Vacuum meter to suction port (by T-fitting), next connect charging hose to vacuum meter and finally service hose to the vacuum pump.
  • Page 38: Check After Installation

    Check after installation • Check according to the following requirement after finishing installation. Items to be checked Possible malfunction Has the unit been installed firmly? The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? It may cause insufficient cooling (heat- ing) capacity.
  • Page 39: Configuration Of Connection Pipe

    Configuration of connection pipe 1. Standard length of connection pipe • 16 ft. 2. Min. length of connection pipe is 9.8 ft. 3. Max. length of connection pipe and max. hight difference. Cooling Max length Cooling Max length Max height capacity of connec- height...
  • Page 40 Configuration of connection pipe Additional refrigerant charging amount for R407C, R410A and R134a Diameter of connection pipe Outdoor unit throttle Liquid pipe Gas pipe Cooling only(oz/ft) Cooling and heating(oz/ft) Φ 1/4’’ Φ3/8’’ or Φ1/2’’ 0.161 0.215 Φ1/4’’ or Φ3/8’’ Φ5/8’’ or Φ3/4’’ 0.161 0.537 Φ1/2’’...
  • Page 41: Pipe Expanding Method

    Pipe expanding method Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: A: Cut the pipe E: Expand the port • Confirm the pipe length according • Expand the port with expander. to the distance of indoor unit and outdoor unit.
  • Page 42 Error Error Code Error Error Code Return air temperature sensor open/ Drive board communication error short circuited Evaporator temperature sensor open/ Compressor overheating protection short circuited Indoor unit liquid valve temperature Indoor and Outdoor units unmatched sensor open/short ciruited Indoor gas valve temperature sensor Communication line misconnected or open/short circuited expansion valve error...
  • Page 43 6700 Gateway Park Dr, Unit 6 San Diego, CA 92154 Ph: +(619) 426 0033 mirageappliances.us...