Installation Of Indoor Unit - Mirage IAEH121A Owner's Manual

Split air conditioner
Table of Contents

Advertisement

Installation of indoor unit

Step one: choosing installation location
Recommend the installation location to the client and then confirm it with
the client.
Step two: install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal
position with the level meter and then point out the screw fixing holes on
the wall.
2. Drill the screw fixing holes on the wall with impact drill (the
specification of drill head should be the same as the plastic expansion
particle) and then fill the plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws
(ST4.2X25TA) and then check if the frame is firmly installed by pulling
the frame. If the plastic expansion particle is loose, please drill another
fixing hole nearby.
Step three: open piping hole
1. Choose the position of piping hole according to the direction of
outlet pipe. The position of piping hole should be a little lower than the
wall-mounted frame, shown as below.
09 12K:
Wall
Mark in the middle of it
Space
to the
wall
above
6''
Left
Rear piping hole
24K:
Wall
Mark in the middle of it
Space
to the
wall
above
6''
Left
Rear piping hole
2. Open a piping hole with the diameter of Φ2.5'' or Φ3'' on the selected
outlet pipe position.In order to drain smoothly, slant the piping hole on the
wall slightly downward to the outdoor side with the gradient of 5-10°.
18K:
Wall
Wall
Level meter
Space
to the
wall
above
6''
Right
Rear piping hole
Wall
Level meter
Space
to the
wall
above
6''
Right
2.5''
Rear piping hole
Mark in the middle of it
Space
to the
wall
above
6''
Left
Rear piping hole
Wall
Level meter
Space
to the
wall
above
6''
Right
Rear piping hole
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Oaeh121aIaeh241aOaeh241a

Table of Contents