3.0 OPERATION INSTRUCTION FOR BOILERS WITH CSD-1 CONTROLS

Initial Start-Up Procedure with Standing Pilot
1. Open the manual gas shut-off supply valve.
2. Close the manual blowdown valve, if so equipped.
3. Light the pilot burner.
The dial on the gas combination valve has three positions (ON - OFF - PILOT) for manual
gas control of main burners and pilot burner. Turn the dial on the gas combination valve to
"PILOT", depress the dial and light the pilot burner on the centre burner. Maintain the dial in
depressed position for about 30 seconds and release. Observe the pilot flame stays ON.
Turn dial to "ON".
If at any time the flame should become extinguished, a five (5) minute purging is
required before relighting is attempted.
4. Open cabinet door and turn "ON" the power switch.
The green pilot light will come "ON". Water should begin to enter the boiler. When enough
water has entered the boiler the (amber) "STANDBY" pilot light will come on.
5. Press the "RESET" switch to begin boiler operation.
The "STANDBY" pilot light will go off and the boiler will begin operation.
Initial Start-Up Procedure with Electronic Ignition
1. Open the manual gas supply valve and water supply. Turn on power supply to the unit.
2. Open cabinet door. With gas control valve, water supply and power switch ON, green
pilot light will come on. Water will begin to enter the boiler. When enough water has
entered the boiler the (amber) "STANDBY" pilot light will come on.
The dial on the gas combination control valve has two positions (ON and OFF).
ON - (Rotated counterclockwise) permits gas to flow to the pilot and main burner.
OFF - (Rotated clockwise) prevents gas flow to pilot and main burner.
NOTE: Units are shipped with the control in the ON position.