INSTALLATION AND OPERATION MANUAL, GAS FIRED PRESSURELESS COOKER WITH
DIRECT STEAM KETTLES, MODELS GCX-2-6, GCX-2-10, GCX-2-6-6 AND GCX-2-6-10
SAFETY LOCKOUT CONDITIONS (Continued)
High Pressure Condition
A high pressure safety switch is installed on the boiler. Should the pressure exceed the limit of
this device, the boiler will be shut down and put into a state of lockout. The "Pressure" pilot light
(red), and the standby pilot light (amber), will come on. Should this device fail to operate, the
safety relief valve will open.
Low Water Condition
A second low water safety cut off is supplied with the boiler. Should the water level fall below
normal operating levels, this device will shut down and put the boiler in a state of lockout. The
"Low Water" pilot light (red), and the "Standby" pilot light (amber) will come on.