INSTALLATION AND OPERATION MANUAL, GAS FIRED PRESSURELESS COOKER WITH
DIRECT STEAM KETTLES, MODELS GCX-2-6, GCX-2-10, GCX-2-6-6 AND GCX-2-6-10
8.0 TROUBLESHOOTING (Continued)
PILOT DOES NOT IGNITE (ELECTRONIC IGNITION) (Continued)
5. Unit in 100% lock out. Turn off and try in five minutes.
6. Dirty flame sensor. Clean with emery cloth.
7. Pilot burner/ignitor sensor, cracked ceramic insulator. Have replaced.
8. Check for too much draft in room.
KETTLE DOES NOT HEAT
1. Steam control valve not turned on.
2. Steam trap not closing.
3. Steam trap not opening to release condensate water.
4. Boiler not producing enough steam pressure.
KETTLE LEAKS STEAM
1. "O" rings are worn. Replace.
2. Steam valve seat worn. Replace seat.
PART NUMBER 10122R1