INSTALLATION AND OPERATION MANUAL, GAS FIRED PRESSURELESS COOKER WITH
DIRECT STEAM KETTLES, MODELS GCX-2-6, GCX-2-10, GCX-2-6-6 AND GCX-2-6-10
SERVICE CONNECTIONS
NOTICE: If this equipment is being installed at over 2,000 feet
altitude and was not so specified on order, contact service
department. Failure to install with proper orifice sizing may void the
warranty.
PLUMBING CONNECTIONS
WARNING: Plumbing connections must comply with applicable
sanitary, safety, and plumbing codes.
WATER SUPPLY CONNECTION
The incoming cold water supply connection, at the rear of the steamer cabinet, requires 3/8"
tubing and water pressure of 25 - 50 psi. A manual shut-off valve must be provided convenient
to the appliance; this valve should be open when the boiler is in operation.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS
NOT COVERED UNDER WARRANTY. SEE WATER QUALITY STATEMENT (PAGE 4.)
DRAIN CONNECTION
The appliance drain (2" IPS) should be piped to a floor drain near the steamer. There should
be no solid drain connection; an "open gap" between the steamer and the floor drain is
required.
GAS CONNECTION
1. The data plate on the cabinet door of the boiler indicates the type of gas your unit is
equipped to burn. DO NOT connect to any other gas type.
Keep the appliance area free and clear from combustible substances. Do not obstruct
the flow of combustion and ventilation air.
2. A 3/4" NPT line is provided at the rear for the connection. Each boiler is equipped with
an internal pressure regulator which is set at 3.5" W.C. manifold pressure for natural
gas or 10.5" W.C. for L.P. gas. Use the 1/8" pipe tap on the burner manifold for
checking pressure.