Preparations Before the Test

Before connecting the tester, clean the battery posts with a wire brush and a
mixture of baking soda and water. When testing side-post batteries, install and
tighten lead terminal adapters.
IMPORTANT: Do not test at steel bolts. Failure to install terminal adapters or
installing terminal adapters that are worn or dirty may result in inac-
curate test results. To avoid damage, never use a wrench to tighten the
adapters more than 1/4 turn.
If you are testing in the vehicle, make sure all accessory loads are off, the key is
not in the ignition, and the doors are closed.

Connecting the Tester

Connect the red clamp to the positive (+) terminal and the black clamp to
the negative (–) terminal.
For a proper connection, rock the clamps back and forth. The tester re-
quires that both sides of each clamp be firmly connected before testing. A
poor connection will produce a CHECK CONNECTION or WIGGLE CLAMPS
message. If the message appears, clean the terminals and reconnect the
clamps.
The preferred test postion is at the battery terminals. If the battery is not
accessible, you may test at the jumper post; however, the available power
measurement may be lower than the actual value.