Preparations Before The Test; Connecting The Tester - Midtronics MDX-652P Instruction Manual

Battery conductance and electrical system analyzer for 6 & 12-volt automotive starting batteries and 12 & 24-volt starting/charging systems
Table of Contents

Advertisement

MDX-652P

Preparations Before the Test

Before connecting the tester, clean the battery posts or side terminals with
a wire brush and a mixture of baking soda and water. When testing side-
post batteries, install and tighten lead terminal adapters. A set of adapters is
included with the tester.
IMPORTANT: Do not test at steel bolts. For OUT-OF-VEHICLE testing,
failure to install terminal adapters or installing terminal adapters that
are worn or dirty may result in inaccurate test results. To avoid dam-
age, never use a wrench to tighten the adapters more than ¼ turn.
If you are testing in the vehicle, make sure all accessory loads are off, the key is
not in the ignition, and the doors are closed.

Connecting the Tester

Connect the red clamp to the positive (+) terminal and the black clamp to
the negative (–) terminal.
For a proper connection, move the clamps back and forth. The tester re-
quires that both sides of each clamp be firmly connected before testing. A
poor connection will produce a CHECK CONNECTION or WIGGLE CLAMPS
message. If the message appears, clean the terminals and reconnect the
clamps.
The preferred test position is at the battery terminals. If the battery is not
accessible, you may test at the jumper post; however, the available power
measurement may be lower than the actual value.