Troubleshooting; Diagnostic Chart - Chamberlain door opener Owner's Manual

Logic 3 industrial duty commercial door operator
Table of Contents

Advertisement

DIAGNOSTIC CHART

The logic board has several LEDs to assist in the installation and troubleshooting of the operator. The following chart should assist in
verifying the operator is functioning properly. Turn the selector dial to DIAGNOSTIC to keep the door from moving while

troubleshooting.

LED
COLOR
Power
Green
Stop
Green
Open
Yellow
Close
Yellow
Eyes
Green
Timer Defeat
Yellow
OLS
Yellow
CLS
Yellow
SLS
Yellow
Edge
Yellow
Mid Stop
Yellow
Timer Enabled
Green
SBC
Yellow
MAS
Yellow
Relay A
Yellow
Relay B
Yellow
T R O U B L E S H O O T I N G
DEFINITION
Indicates that power is being generated for the logic board.
Indicates a closed circuit between common and terminal 5. Pressing stop should turn off this LED.
Indicates a closed circuit between common and terminal 7. Pressing the open button should turn
ON this LED.
Indicates a closed circuit between common and terminal 6. Pressing the close button should turn
ON this LED.
Solid on indicates photo eyes learned. Flashing indicates photo eyes need to be connected or obstructed.
Solid off indicates no eyes learned.
Solid on indicates a closed circuit between common and terminal 12. Timer to close will not close.
Pressing the Open Limit Switch should turn ON this LED.
Pressing the Close Limit Switch should turn ON this LED.
Pressing the Sensing Limit Switch should turn ON this LED.
Indicates a closed circuit between common and terminal 8. Pressing the edge should turn ON this LED.
Solid on indicates door is stopped on up or down mid stop. Flashing indicates MID STOP is being set.
Solid on indicates TIMER is programmed and will activate from open or mid stop position. Flashing
indicates Timer is counting down and door will close after preset time.
Indicates a closed circuit between common and terminal 1. Pressing the single button control station
should turn ON this LED.
Indicates the Maintenance Alert System has been activated or an error code has been triggered.
Indicates open or close command has been given to the motor. LED turns on when OPEN/CLOSE button is
pressed.
Indicates open or close command has been given to the motor. LED turns on when OPEN/CLOSE button is
pressed.