Entrapment Protection Accessories; Adjustment; Limit Switch Adjustment - Chamberlain door opener Owner's Manual

Logic 3 industrial duty commercial door operator
Table of Contents

Advertisement

ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL)
PHOTO EYES AND SENSING EDGES
Sensing devices provided for door industry type operators with an
isolated normally open (N.O.) dry contact output are compatible
with your operator. This includes pneumatic and electric edges,
and through beam and retro reflective photo eyes. If you would
like to order or receive more information on safety devices, please
contact your local Authorized Dealer.
If not pre-installed by the door manufacturer, mount the sensing
edge on the door according to the instructions provided with the
edge. The sensing edge may be electrically connected by either
coiled cord or take-up reel.
Important Notes:
a. Proceed with limit switch adjustments described below before
making any sensing edge wiring connections to operator.
b. Electrician must hardwire the junction box to the operator
electrical box in accordance with local codes.
WARNING

LIMIT SWITCH ADJUSTMENT

CAUTION
NOTE: Make sure the limit nuts are positioned between the limit
switches before proceeding with adjustments.
1. Depress retaining plate to allow nut to spin freely. After
adjustment, release plate and move nut back and forth to
ensure it is fully seated in slot.
2. To increase door travel, spin nut away from limit switch. To
decrease door travel, spin limit nut toward limit switch.
3. Adjust open limit nut so that door will stop in open position
with the bottom of the door even with top of door opening.
4. Repeat steps 1 and 2 for close cycle. Adjust close limit nut so
that the limit switch is engaged as door fully seats at the floor.
AVERTISSEMENT
ATTENTION
SAFETY
(Aux. Close) Limit Switch
CLOSE Limit Switch
I N S T A L L A T I O N
To prevent possible SEVERE INJURY or DEATH, install
reversing sensors when:
• The radio is used.
• The 3-button control station is out of sight of the door.
• Or ANY other control (automatic or manual) is used.
Reversing devices are recommended for ALL installations.
WIRING
For wiring of your sensing device to the operator, refer to the
wiring diagrams provided on pages 13 and 14. See field
connection terminals identified as Reversing Device.
TAKE-UP REEL
Take-up reel should be installed 12" (30.48 cm) above the top of
the door.
COIL CORD
Connect operator end of coil cord to junction box (not provided)
fastened to the wall approximately halfway up the door opening.
A D J U S T M E N T
To avoid SERIOUS personal INJURY or DEATH from
electrocution, disconnect electric power BEFORE manually
moving limit nuts.
CLOSE
OPEN
8
WARNING
WARNING
CAUTION
AVERTISSEMENT
ATTENTION
WARNING
WARNING
WARNING
ADVERTENCIA
AVERTISSEMENT
PRECAUCIÓN
AVERTISSEMENT
OPEN Limit Switch