Diagnostic Chart
Your garage door opener is programmed
with self-diagnostic capabilities. The UP
and DOWN arrows on the garage door
opener flash the diagnostic codes.
DIAGNOSTIC CODE
Up Arrow
Down Arrow
Flash(es)
Flash(es)
1
1
1
2
1
3
1
4
1
5
1
6
2
1-5
3
1
3
2
3
3
3
5
4
1-4
4
5
4
6
5
5
SYMPTOM
The garage door opener
will not close.
The garage door opener
will not close.
The door control will not
function.
The garage door opener
will not close, and the
lights flash.
Door moves 6-8"
(15-20 cm) stops or
reverses.
No movement, only a
single click.
Opener hums for 1-2
seconds no movement.
Door coast after it has
come to a complete stop.
No movement or sound.
The garage door opener
moves slightly, then stops
The garage door opener
reverses right before the
door is fully closed.
The battery status LED is
constantly blinking green.
The garage door will not
close. Door reverses during
close travel direction only.
Door is moving, stops or
reverses. Opener beeps
and lights flash.
Opener runs approximately
6-8" (15-20 cm), stops and
reverses.
The garage door opener
will not close, and the
lights flash.
The door will not close
when using Timer-to-
Close or myQ Smartphone
Control
SOLUTION
Safety sensors are not installed, connected or wires may be cut. Inspect sensor
wires for a disconnected or cut wire.
There is a short or reversed wire for the safety sensors. Inspect safety sensor
wire at all staple points and connection points and replace wire or correct as
needed.
The wires for the door control are shorted or the door control is faulty. Inspect
door control wires at all staple points and connection points and replace wire or
correct as needed.
Safety sensors are misaligned or were momentarily obstructed. Realign both
sensors to ensure both LEDs are steady and not flickering. Make sure nothing
is hanging or mounted on the door that would interrupt the sensors path while
closing.
Manually open and close the door. Check for binding or obstructions, such as
a broken spring or door lock, correct as needed. Check wiring connections at
travel module and at the logic board. Replace travel module if necessary.
Manually open and close the door. Check for binding or obstructions, such as a
broken spring or door lock, correct as needed. Replace logic board if necessary.
Manually open and close the door. Check for binding or obstructions, such as a
broken spring or door lock, correct as needed. Replace motor if necessary.
Program travel to coasting position or have door balanced by a trained
technician.
Replace logic board.
Activate the garage door opener again. If problem persists, replace logic board.
Check to see if door is working properly. Clears when opener runs full cycle.
Battery backup charging circuit error, replace logic board.
• Check that the CTM Learn is appropriate to the installation.
• Check for possible door obstructions and remove.
• Replace defective CTMs with good CTMs to clear the error code (see optional
CTM accessory).
Manually open and close the door. Check for binding or obstructions, such as a
broken spring or door lock, correct as needed. If the door is binding or sticking
contact a trained door systems technician. If door is not binding or sticking
attempt to reprogram travel.
Communication error to travel module. Check travel module connections, replace
module if necessary.
Safety sensors are misaligned or were momentarily obstructed. Realign both
sensors to ensure both LEDs are steady and not flickering. Make sure nothing
is hanging or mounted on the door that would interrupt the sensor's path while
closing.
myQ Remote LED Light must be installed to use TTC or myQ to control the
door. Plug in the myQ Remote LED Light and make sure it is programmed to the
garage door opener.
UP Button