Function Parameters
Acceleration/deceleration reference
20
frequency
Acceleration/deceleration time
21
increments
22
Stall prevention operation level
Stall prevention operation level
23
compensation factor at double speed
24
Multi-speed setting (4 speed to 7
to
speed)
27
Multi-speed input compensation
⎯
28
selection
29
Acceleration/deceleration pattern
⎯
selection
30
⎯
Regenerative function selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
⎯
Speed display
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for
43
reverse rotation
Second acceleration/deceleration
44
time
45
Second deceleration time
46
Second torque boost
47
Second V/F (base frequency)
Second stall prevention operation
48
current
Second stall prevention operation
49
frequency
50
Second output frequency detection
51
Second electronic thermal O/L relay
52
DU/PU main display data selection
54
CA terminal function selection
55
Frequency monitoring reference
56
Current monitoring reference
Name
1 to 400Hz
0, 1
0 to 120%, 9999
0 to 150%, 9999
0 to 400Hz, 9999
0, 1
0, 1, 2, 3, 6
0, 2, 10, 20, 100, 120/
0, 1, 2, 10, 11, 20, 21,
100, 101, 120, 121
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0, 1 to 9998
0 to 100%
0 to 400Hz
0 to 400Hz, 9999
0 to 3600/360s
0 to 3600/360s, 9999
0 to 30%, 9999
0 to 400Hz, 9999
0 to 120%
0 to 400Hz, 9999
0 to 400Hz
0 to 500A, 9999/
0 to 3600A, 9999
0, 5, 6, 8 to 14, 17, 20,
23 to 25, 50 to 57, 64,
67, 81 to 86, 100
1 to 3, 5, 6, 8 to 14, 17,
21, 24, 50, 52, 53, 67,
70, 85
0 to 400Hz
0 to 500A/0 to 3600A
Minimum
Setting Range
Setting
Increments
0.01Hz
1
0.1%
0.1%
0.01Hz
1
1
1
*2
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
1
0.1%
0.01Hz
0.01Hz
0.1/0.01s
0.1/0.01s
0.1%
0.01Hz
0.1%
0.01Hz
0.01Hz
0.01/0.1A
*2
*2
1
1
0.01Hz
0.01/0.1A
*2
*2
Parameter list
Refer
Initial
Customer
to
Value
Setting
Page
60Hz
101
0
101
110%
81
9999
81
9999
93
0
97
0
105
0
115
9999
88
9999
88
9999
88
9999
88
9999
88
9999
88
0
141
10%
135
6Hz
135
9999
135
5s
101
9999
101
9999
78
9999
89
110%
81
0Hz
81
30Hz
135
9999
107
0
143
1
143
60Hz
149
Rated
inverter
149
current
63
4