Mitsubishi FR-F720-00046-NA Instruction Manual page 185

Table of Contents

Advertisement

Inverter
Forward
STF
rotation
Voltage/current
input switch
SD
4
0 to 5VDC
10
Frequency
2
setting
5
Connection diagram using
terminal 2 (0 to 5VDC)
Inverter
Forward
STF
Voltage/current
input switch
rotation
SD
4
0 to 10VDC
10E
Frequency
2
setting
5
Connection diagram
using terminal 2 (0 to 10VDC)
Inverter
Forward
rotation
STF
Terminal 4
AU
input selection
SD
DC0 to 5V
10
Frequency
4
setting
5
Connection diagram
using terminal 4 (0 to 5VDC)
Forward
STF
rotation
AU
SD
4 to 20mADC
Current
4
Frequency
input
setting
equipment
5
Connection diagram using
terminal 4 (4 to 20mADC)
Forward
STF
rotation
SD
4 to 20mADC
Current
2
Frequency
input
setting
equipment
5
Connection diagram using
terminal 2 (4 to 20mADC)
(2) Perform operation by analog input voltage
⋅ The frequency setting signal inputs 0 to 5VDC (or 0 to 10VDC) to across
the terminals 2 and 5. The 5V (10V) input is the maximum output
frequency. The maximum output frequency is reached when 5V (10V) is
2
input.
⋅ The power supply 5V (10V) can be input by either using the internal
power supply or preparing an external power supply. The internal power
supply outputs 5VDC across terminals 10 and 5, or 10V across terminals
10E and 5.
Terminal
10
10E
2
⋅ When inputting 10VDC to the terminal 2, set any of "0, 2, 4, 10, 12, 14"
in Pr. 73. (The initial value is 0 to 5V)
⋅ Setting "1 (0 to 5VDC)" or "2 (0 to 10VDC)" in Pr. 267 and a voltage/
current input switch in the OFF position changes the terminal 4 to the
voltage input specification. When the AU signal turns ON, the terminal 4
input becomes valid.
Voltage/current
input switch
4
2
REMARKS
The wiring length of the terminal 10, 2, 5 should be 30m (98.4 feet) maximum.
(3) Perform operation by analog input current
Inverter
⋅ When the pressure or temperature is controlled constant by a fan, pump,
etc., automatic operation can be performed by inputting the output signal
Voltage/current
input switch
4 to 20mADC of the adjuster to across the terminals 4 and 5.
4
2
⋅ The AU signal must be turned ON to use the terminal 4.
⋅ Setting any of "6, 7, 16, 17" in Pr. 73 and a voltage/current input switch in
Inverter
the ON position changes the terminal 2 to the current input specification.
Voltage/current
input switch
At this time, the AU signal need not be turned ON.
4
2
Frequency setting by analog input (terminal 1, 2, 4)
Inverter Built-in Power
Frequency Setting
Supply Voltage
Resolution
5VDC
0.030Hz/60Hz
10VDC
0.015Hz/60Hz
Pr. 73 (terminal 2
input voltage)
0 to 5VDC input
0 to 10VDC input
4
175