Setting
Signal
Positive
Negative
Name
Logic
Logic
Output current
12
112
Y12
detection
Zero current
13
113
Y13
detection
14
114
FDN
PID lower limit
15
115
FUP
PID upper limit
PID forward/reverse
16
116
RL
rotation output
17
MC1
Electronic bypass MC1
18
MC2
Electronic bypass MC2
19
MC3
Electronic bypass MC3
25
125
FAN
Fan fault output
Heatsink overheat
26
126
FIN
pre-alarm
Inverter running and
45
145
RUN3
start command is ON
During deceleration at
46
146
Y46
occurrence of power
failure
During PID control
47
147
PID
activated
48
148
Y48
PID deviation limit
During pre-charge
49
149
Y49
operation
During second pre-
50
150
Y50
charge operation
51
151
Y51
Pre-charge time over
Second pre-charge
52
152
Y52
time over
53
153
Y53
Pre-charge level over
Second pre-charge
54
154
Y54
level over
64
164
Y64
During retry
67
167
Y67
During power failure
PID output
70
170
SLEEP
interruption
Function
Output when the output current is higher
than the Pr. 150 setting for longer than the
time set in Pr. 151.
Output when the output power is lower than
the Pr. 152 setting for longer than the time
set in Pr. 153.
Output when the feedback value falls below
the lower limit of PID control.
Output when the feedback value rises above
the upper limit of PID control
Output when forward rotation is performed in
PID control.
Used when the bypass-inverter switchover
function is used.
Output at the time of a fan alarm.
Output when the heatsink temperature
reaches about 85% of the heatsink overheat
protection operation temperature.
Output when the inverter is running and start
command is ON.
Output when the power failure-time
deceleration function is executed.
(retained until release)
Output during PID control.
Output when the absolute value of deviation
exceeds the limit value.
Output during the pre-charge operation.
Output when the pre-charged time exceeds
the time set in Pr.764 or Pr.769.
Output when the pre-charged amount
exceeds the set level in Pr.763 or Pr.768.
Output during retry processing.
Output during output shutoff due to power
failure or under voltage.
Output when the PID output interruption
function is executed.
Function assignment of external
Operation
terminal and control
Related
Refer
Parameters
to Page
Pr. 150, Pr. 151
137
Pr. 152, Pr. 153
137
Pr. 127 to Pr. 134,
263
Pr. 575 to Pr. 577
Pr. 135 to Pr. 139,
294
Pr. 159
Pr. 244
301
340
133
Pr. 261 to Pr. 266
158
Pr. 127 to Pr. 134,
263
Pr. 575 to Pr. 577
Pr. 127 to Pr. 134,
Pr. 241, Pr. 553, Pr.
263
554, Pr. 575 to Pr.
577, C42 to C45
263,
277
263,
277
Pr. 127 to Pr. 134,
263,
Pr. 241, Pr. 553,
277
Pr. 554,
Pr. 575 to Pr. 577,
263,
Pr. 753 to Pr. 769,
277
C42 to C45
263,
277
263,
277
Pr. 65 to Pr. 69
161
Pr. 57
157
Pr. 127 to Pr. 134,
263
Pr. 575 to Pr. 577
131
4