Mitsubishi FR-F720-00046-NA Instruction Manual page 255

Table of Contents

Advertisement

Parameter
Parameters Register
41000 to
Refer to the parameter list (page
0 to 999
41999
62) for the parameter names.
Terminal 2 frequency setting
C2(902)
41902
bias (frequency)
Terminal 2 frequency setting
42092
bias (analog value)
C3(902)
Terminal 2 frequency setting
43902
bias (terminal analog value)
Terminal 2 frequency setting
125(903)
41903
gain (frequency)
Terminal 2 frequency setting
42093
gain (analog value)
C4(903)
Terminal 2 frequency setting
43903
gain (terminal analog value)
Terminal 4 frequency setting
C5(904)
41904
bias (frequency)
Terminal 4 frequency setting
42094
bias (analog value)
C6(904)
Terminal 4 frequency setting
43904
bias (terminal analog value)
Terminal 4 frequency setting
126(905)
41905
gain (frequency)
Terminal 4 frequency setting
42095
gain (analog value)
C7(905)
Terminal 4 frequency setting
43905
gain (terminal analog value)
C8(930)
41930
Current output bias signal
C9(930)
42120
Current output bias current
C10(931)
41931
Current output gain signal
C11(931)
42121
Current output gain current
C42(934)
41934
PID display bias coefficient
42124
PID display bias analog value
C43(934)
PID display bias analog value
43934
(terminal analog value)
C44(935)
41935
PID display gain coefficient
42125
PID display gain analog value
C45(935)
PID display gain analog value
43935
(terminal analog value)
Parameter Name
Read/Write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Communication operation and setting
Remarks
The parameter number + 41000 is the
register number.
The analog value (%) set to C3 (902) is
read.
The analog value (%) of the voltage (current)
Read
applied to the terminal 2 is read.
The analog value (%) set to C4 (903) is
read.
The analog value (%) of the voltage
Read
(current) applied to the terminal 2 is read.
The analog value (%) set to C6 (904) is
read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
The analog value (%) set to C7 (905) is
read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
The analog value (%) set to C43 (934) is
read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
The analog value (%) set to C45 (935) is
read.
The analog value (%) of the current
Read
(voltage) applied to the terminal 4 is read.
4
245

Advertisement

Table of Contents
loading

Table of Contents