Mitsubishi FR-F720-00046-NA Instruction Manual page 325

Table of Contents

Advertisement

Acceleration/deceleration time increment (Pr. 999
Parameter
7
Acceleration time
8
Deceleration time
Jog acceleration/deceleration
16
time
Acceleration/deceleration time
21
increments
Second acceleration/
44
deceleration time
45
Second deceleration time
Power-failure deceleration time
264
1
Power-failure deceleration time
265
2
Auxiliary motor connection-time
582
deceleration time
Auxiliary motor disconnection-
583
time acceleration time
* The set value is changed for Pr. 21.
REMARKS
When a parameter is set as the acceleration/deceleration time (0.1s), the 0.01s increment is dropped.
When a parameter is set as the acceleration/deceleration time (0.01s), the parameters are limited at the maximum value of the
parameter setting range. For example, Pr. 7 = "361.0s" when 0.1s increment is selected, and Pr. 7 = "360.00s" when 0.01s
increment is selected.
="30(0.1s) or 31(0.01s)")
 
Initial set
Name
increment
0.1s
0.1s
0.1s
1
0.1s
0.1s
0.1s
0.1s
0.1s
0.1s
Pr.999 = "30"
Pr.999 = "31"
0.1s
0.1s
0.1s
0
*
0.1s
0.1s
0.1s
0.1s
0.1s
0.1s
Useful functions
Refer to
page
0.01s
101
0.01s
101
0.01s
95
1
101
*
0.01s
101
0.01s
101
0.01s
158
0.01s
158
0.01s
284
0.01s
284
315
4

Advertisement