System Requirements - Gree NEO09AC115V1A Installation Manual

Hide thumbs Also See for NEO09AC115V1A:
Table of Contents

Advertisement

SYSTEM REQUIREMENTS

Piping Requirements
PIPE SIZE in (mm)
Unit Size
(BtuH)
9,000
12,000
9,000
12,000
18,000
24,000
30,000
36,000
REFRIGERANT LINE LENGTHS ft (m)
Unit Size
(BtuH)
9,000
12,000
9,000
12,000
18,000
24,000
30,000
36,000
Notes:
Insulate both refrigerant lines, separately.
REFRIGERANT CHARGE
Unit Size
(BtuH)
9,000
12,000
9,000
208/230v - 1ph 60hz
12,000
208/230v - 1ph 60hz
18,000
208/230v - 1ph 60hz
24,000
208/230v - 1ph 60hz
30,000
208/230v - 1ph 60hz
36,000
208/230v - 1ph 60hz
*Precharge amount for up to 25-ft of refrigerant pipe.
ELECTRICAL REQUIREMENTS
Unit Size
(BtuH)
9,000
12,000
9,000
208/230v - 1ph 60hz
12,000
208/230v - 1ph 60hz
18,000
208/230v - 1ph 60hz
24,000
208/230v - 1ph 60hz
30,000
208/230v - 1ph 60hz
36,000
208/230v - 1ph 60hz
**Main power wire from electrical panel to outdoor unit.
Notes:
1) System must be on a single dedicated circuit.
2) Main power is supplied to the outdoor unit.
3) Use table above to size over current protection.
4) Follow all local building codes and NEC (National Electrical Code) regulations.
Interconnecting Cable: Recommended cable - 14/4 AWG stranded bare copper conductors THHN 600V unshielded wire
Note: Use shield cable if installation is in close proximity of RF and EMI transmitting devices.
Condensate Drain Size: 5/8-in OD 7/16-in ID
Note: Insulate condensate drain hose to prevent sweating and possible water damage.
Voltage
115v - 1ph 60hz
115v - 1ph 60hz
208/230v - 1ph 60hz
208/230v - 1ph 60hz
208/230v - 1ph 60hz
208/230v - 1ph 60hz
208/230v - 1ph 60hz
208/230v - 1ph 60hz
Voltage
115v - 1ph 60hz
115v - 1ph 60hz
208/230v - 1ph 60hz
208/230v - 1ph 60hz
208/230v - 1ph 60hz
208/230v - 1ph 60hz
208/230v - 1ph 60hz
208/230v - 1ph 60hz
Voltage
115v - 1ph 60hz
115v - 1ph 60hz
Voltage
115v - 1ph 60hz
115v - 1ph 60hz
Min Line
Length
10 (3)
10 (3)
10 (3)
10 (3)
10 (3)
10 (3)
10 (3)
10 (3)
Refrigerant
Factory System
Type
Charge oz (kg)*
R410A
R410A
R410A
R410A
R410A
R410A
R410A
R410A
Min Circuit
Max Overcurrent
Amps (MCA)
Protection (MOP)
22
23
10
10
13
16
20
24
Liquid Line
Suction/Gas Line
1/4 (6)
1/4 (6)
1/4 (6)
1/4 (6)
1/4 (6)
1/4 (6)
1/4 (6)
1/4 (6)
Max Line
Length
50 (15)
50 (15)
50 (15)
66 (20)
82 (25)
82 (25)
100 (30)
100 (30)
Charge oz/ft (g/m)
42.9 (1.2)
46.4 (1.3)
46.4 (1.3)
46.4 (1.3)
49.4 (1.4)
56.5 (1.6)
84.7 (2.4)
91.7 (2.6)
Wire Size (AWG)**
35
40
15
15
20
25
30
40
3/8 (9.5)
3/8 (9.5)
3/8 (9.5)
3/8 (9.5)
1/2 (12)
5/8 (16)
5/8 (16)
5/8 (16)
Max Elevation
(ID over OD)
33 (10)
33 (10)
33 (10)
33 (10)
33 (10)
33 (10)
33 (10)
33 (10)
Additional
0.2 (20)
0.2 (20)
0.2 (20)
0.2 (20)
0.2 (20)
0.5 (50)
0.5 (50)
0.5 (50)
Main Power
10
10
14
14
12
10
10
10
4

Advertisement

Table of Contents
loading

Table of Contents