  • Page 1 Use/Installation GUIDE 5 SERIES Rear Downdraft Ventilators VDD5300 VDD5360 VDD5450 VDD5480...
  • Page 2 MODEL WIDTH BLOWER (purchased separately) VDD5300 30" W. VDVI600 Interior or VDVE900 Exterior VDD5360 36" W. VDVI600 Interior or VDVE900 Exterior VDD5450 45" W. VDVI600 Interior or VDVE900 Exterior, VDVE1200 Exterior VDD5480 48" W. VDVI600 Interior or VDVE900 Exterior, VDVE1200 Exterior...
  • Page 3: Plan The Ductwork

    CONTENTS Note: Remove all protective film and packaging before op- eration. In order to remove all protective film and packag- These parts are included with your downdraft housing: ing, raise the ventilator housing and remove the front panel 1 - Parts Bag to access the filter area.
  • Page 4 PLAN CABINET CUTOUTS PREPARE THE DOWNDRAFT CAUTION: FRONT PANEL COVER BEFORE CUTTING HOLE IN CABINET FOR DUCTWORK, check for interference with floor joists, wall studs, electrical wiring, or plumbing. CLAMP CHANNEL INSTALLATION CENTER LINE (4-6) HEX NUTS 6 ” FLUSH HOLE INSIDE CABINET BACK...
  • Page 5 8" OR 10" ROUND SLIDE CHANNEL REMOTE DISCHARGE PLATE (Purchase Separatly) COVER PLATE UPPER SUPPORT BRACKET COVER PLATES Flex Blower shown LOWER installed. FRONT CHANNEL PANEL Installations using FLEX BLOWER (in remote location) LONG OR or REMOTE BLOWER only: SHORT SUPPORT 4.
  • Page 6 (4) SCREWS Installations where ELECTRICAL PANEL needs to be mounted in a remote location only: 6. Remove (4) HEX NUTS and ELECTRICAL PANEL. 5-ft. extension cables (purchase separately) may be needed to BLOWER mount electrical panel in a remote location. Do not use more SUPPORT that 2 extension cables.
  • Page 7 CUT COUNTERTOP OPENING 1. Lay out and cut the cooktop cut-out far enough FORWARD so downdraft will fit behind it. 2. Set cooktop in place and slide it as far forward as possible without exposing an gaps. Center and square it with edges of countertop.
  • Page 8: Install Ductwork

    INSTALL DUCTWORK Installations using REMOTE BLOWER only: CAUTION: All electrical wiring should be done by a CAUTION: Before cutting hole in cabinet for qualified person(s) in accordance with all applicable ductwork, check for interference with floor joists, codes and standards. wall studs, electrical wiring, or plumbing.
  • Page 9 INSTALL FINISH TRIM INSTALL COOKING APPLIANCE 1. Align the cooking appliance with downdraft and fasten SCREW appliance in place following appliance instructions. Note: Accurate alignment of cooking appliance and downdraft is necessary to ensure that there is no interference when air vent FINISH is raised and lowered.
  • Page 10: Operation

    OPERATION 4-Speed Fan Speed Control 4-Speed Fan Speed Control Press + button to increase fan speed. Press - button to decrease fan speed. After maximum speed is reached, press + button once more to turn off fan. 2-Level Task Light 2-Level Task Light Press once for LOW setting.
  • Page 11: Service Information

    Always turn the downdraft blower on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a Contact Viking Range, LLC, 1-888-(845-4641), for the nearest few minutes to clean the air after you turn the cooktop off. This service parts distributor in your area or write to: will keep the whole kitchen cleaner and brighter.
  • Page 12: Warranty

    Downdrafts and all of their component parts, except as detailed below*†, are warranted to be free from defective materials or workmanship in normal residential use for a period of one (1) year from the date of original retail purchase. Viking Range, LLC, warrantor, agrees to repair or replace, at its option, any part which fails or is found to be defective during the warranty period.