Alarms; Door (Drawer) Ajar; Power Failure; Temperature Alarm - Viking VDUI5240 Install, Use, & Care Manual

Refrigerated drawers
Table of Contents

Advertisement

Available languages

Available languages

Alarms:

The control will alert you to conditions that could adversely
affect the performance of the appliance.
Door Ajar
Door ajar -
If a drawer is open, or not closed
properly, for more than 5-minutes the System Status
OK indicator will turn-off, the "Door Ajar" indicator
will fl ash, and a tone will sound every 60 seconds.
Additionally, an "ALARM RESET" indicator will be
displayed below the "On/Off" keypad.
NOTE
The audible alarm can be muted, for each occurrence, by
pressing the lock keypad.
This alarm condition can be reset by closing the drawer or
momentarily pressing the "On/Off" keypad, (i.e.-if you are
cleaning the storage compartment, etc.). The alarm will
recur in 5-minutes if the alarm condition persists.

Power Failure

Power failure -
If power to the appliance is inter-
rupted the System Status indicator will turn-off and
the "Power Failure" indicator will fl ash. Additionally,
an "ALARM RESET" indicator will be displayed below
the "On/Off" keypad. No audible tone will sound.
This alarm condition can be reset by momentarily
pressing the "On/Off" keypad. If this alarm occurs, it
is recommended that you check the condition of any
perishables, even if the appliance is operating normally
and the temperature has recovered, as prolonged
power outages could result in excessive temperature
excursions which may spoil perishables.
Temp

Temperature alarm -

temperature deviates excessively from your set-
point temperature for an extended period of time, the
"TEMP" indicator will fl ash, and an audible tone will
sound every 60 seconds. Additionally, an "ALARM
RESET" indicator will be displayed below the "ON/
OFF" keypad.
USING YOUR ELECTRONIC CONTROL
ALARM RESET
ALARM RESET
ALARM RESET
If the storage compartment
NOTE
After a high temperature alarm condition, check all
perishables to ensure they are safe for consumption.
NOTE
The temperature alarm may occur as a result of high
usage or introduction of warm contents to the storage
compartment. If the temperature alarm continues to occur,
your unit may require service.
NOTE
The audible alarm can be muted, for each occurrence,
by pressing the lock keypad.
This alarm condition can be reset by momentarily pressing
the "On/Off" keypad. If this alarm occurs it is recommended
that you check the condition of your stored contents,
even though the appliance is operating normally and the
temperature has recovered, as prolonged temperature
excursions could spoil perishables.
NOTE
Multiple alarms are possible, i.e.- "Door Ajar" for a
prolonged period may trigger a "Temp" alarm, in which case
both "Door Ajar" and "Temp" indicators will activate.