TABLE OF CONTENTS Warnings & Important Safety Instructions_______________________________________________________________________3 Dimensions (Professional) ____________________________________________________________________________________5 Dimensions (Custom Panel)___________________________________________________________________________________6 Specifications ______________________________________________________________________________________________7 Cutout Dimensions __________________________________________________________________________________________7 Drain/Electrical Locations ____________________________________________________________________________________8 General Information _________________________________________________________________________________________9 Air Flow ___________________________________________________________________________________________________9 Filters and Treatment ________________________________________________________________________________________9 Installation Overview _______________________________________________________________________________________10 Accessory Door Panel_______________________________________________________________________________________10 Custom Panel _____________________________________________________________________________________________10 Door Panel Attachment _____________________________________________________________________________________12 Door Swing Change ________________________________________________________________________________________13 Water and Drain Installation _________________________________________________________________________________14...
• The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture. • Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below.
Page 4
PROPER DISPOSAL (OF OLD REFRIGERATION UNIT) DANGER RISK OF CHILD ENTRAPMENT Before You Throw Away Your Old Refrigeration Unit: • Take off the doors. • Leave the shelves in place so that children may not easily climb inside. IMPORTANT: Child entrapment and suffocation are not problems of the past. Junked or abandoned refrigeration units are still dangerous...
GENERAL INFORMATION AIR FLOW The machine takes in room temperature air at the lower right front and forces warm air out the lower left front. Restricting the airflow will adversely affect the ability of the ice machine to make ice. Filters and Treatment In general, it is always a good idea to filter the water.
INSTALLATION OVERVIEW The ice machine must: • Be connected to cold, potable water. • Be connected to a drain. • Be connected to the proper power supply. • Be able circulate air through the vents at the front. Note: DO NOT build in so that the door is recessed. Door is meant to be flush with surronding cabinetry, but not recessed.
Page 11
6. Cut panel to length (cabinet space - kickplate space - top clearance = length). 7. Determine top of panel. 8. Mark hole locations using drawing on the back of these instructions. Drawing assumes top of panel will be flush with top of door.
DOOR SWING CHANGE The door can be attached to open with hinges on the left or right using new brackets shipped loose in the ice bin. Retain all screws for re-use. To change: Inner screw 1. Remove inner screw holding each hinge to cabinet, loosen the outer screw. 2.
WATER & DRAIN INSTALLATION The recommended water supply tubing is 1/4” OD copper. Stainless steel flex or reinforced PVC tube may also be used. Install an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be installed behind the unit.
Page 15
Gravity Drain Pump Model drain installation CAUTION Restrictions in the drain system to the machine will cause water to back up into the ice storage bin and melt the ice. Gravity drain tubing must be vented, have no kinks and slope to the building drain. Air gaps are typically required by local code. 1.
ELECTRICAL CONNECTION WARNING ELECTRICAL SHOCK HAZARD Failure to follow these instructions could result in fire or electrical shock. The ice machine is supplied with a power cord. DO NOT remove the grounding pin from the cord’s plug. DO NOT use extension cords. Follow all codes. Connect Grounding type the machine to its own 115 volt, 15 amp circuit.
Clearly describe the problem that you are having. If you are unable to obtain the name of an authorized service agency, or if you continue to have service problems, contact Viking Range Corporation at 1-888- (845-4641), or write to: VIKING RANGE, LLC...
Page 20
Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit our web site at vikingrange.com 070778-000 EN (121518) 17-3695-01...