Page 1
IMPORTANT SAFETY INSTRUCTIONS Carefully read the following important information regarding installation safety and maintenance. Keep these instructions for future reference. 1 3 03 18/09/2017...
Important Safety Notice Read all Instructions before Installing and operating this appliance • The installation in this manual is intended for quali ed installers, service technicians or persons with similar quali ed background. Installation and electrical wiring must be done by quali ed profession- als and in accordance with all applicable codes and standards, including re-rated construction.
Page 3
• Clean ventilating fan frequently. • Always use appropriate cookware and utensils size. • Always use cookware appropriate for the size of the surface element. To reduce the risk of injury to persons in the event of a stove top grease fire: •...
Page 5
Chimney- • Vent system must terminate to the outside mounting (roof or side wall). bracket Maximum ceiling • DO NOT terminate the vent system in an clearance 110" at attic or other enclosed area. Upper 30" hood mounting • DO NOT use 4” (10.2 cm) laundry-type wall Chimney caps.
IMPORTANT: • A minimum of 6” round (standard for this range hood) or 3-1/4 x 10” rectangular duct (purchased separate- ly) must be used to maintain maximum air ow ef ciency. • Always use rigid type metal/aluminum ducts if available to maximize air ow when connecting to provided duct.
Venting methods: • This range hood is factory set for venting through the roof or wall. • Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed. IMPORTANT: • NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
Page 8
Electrical Requirements : IMPORTANT: Observe all governing codes and ordinances. It is the customer’s responsibility: li i i l i s ll is s i is li i i l s l is si s li i IMPORTANT: Save this Installation Guide for electrical inspector’s use. The range hood must be connected with copper wire/plug only.
Page 9
Preparation: Advanced Preparations: • Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. • Place the range hood on a at, stable surface. Connect the range hood to a designated standard outlet (120-Volt, 60Hz, AC only) and turn on the range hood.
Installation: Installations (refer to Page 4 for parts): 1. Measure the distance between stove top and the bottom of range hood. A distance of 24” to 30” is recommended with a minimum of 30” for gas stove tops. 2. Using references in Height & Clearance on Page 5 and Measurements and Diagrams on Page 16, mark the leveling point of the hood.
Page 11
Installation (Continued): 8. Connect the range hood to a designated standard outlet (120-Volt, F F i i g g u u r r e e 8 8 60Hz, AC only) or cut off the plug and connect three wires (black, white and green) to house wires and cap with wire connectors.
Range Hood Operations: Control Panel Layout and Buttons Configurations: LED Light LED Speed Indicator Indicators Power Control Light Control Speed Control (On/Off) This range hood is equipped with six electronic controls, oversized powerful centrifugal squirrel cage motor with stainless steel baf e lters and spacers, two bright 3 W LED lights. The six electronic buttons control the intensity of the Lights, Speeds ( uiet, Low, Medium and High) and Power (On/Off).
Page 13
Range Hood Operations (Continued): Control Panel Layout and Buttons Configurations: uiet Medium High Speed Speed Speed Speed LED Light LED Speed Indicator Indicators Light Control Power Control (On/Off) • During this 3-minutes delay, changing speeds will not affect the countdown. e iate o er-o •...
Troubleshooting 1. If the range hood or LED light does not operate • Check if the range hood has been plugged in, make sure that all power has been turned back ON, fused after installation: not blown and all electrical wiring are properly con- nected.
Use and Care Information: Operations: • Read and understand all instructions and warnings in this manual before operating the appliance. Save these instructions for future reference. • Always leave safety grills and lters in place. Without these components, operating blowers could catch on to hair, ngers and loose clothing.
Page 16
Measurements and diagrams: Inst ll tion er ie...
Page 17
All measurements in parenthesis are in • • All inch measurements are converted from s, thus inch measurements are estimated. Overall:...
Page 18
• All measurements in parenthesis are in • All inch measurements are converted from s, thus inch measurements are estimated. Overall without Chimney:...
Maintenance: SAFETY WARNING: Never put your hand into area housing the fan while the fan is operating! For optimal operation, clean range hood and all baf e/spacer/ lter/oil container regularly. Regular care will help preserve the appearance of the range hood. Cleaning Exterior surfaces: •...
Need help?
Do you have a question about the WPRO 30 and is the answer not in the manual?
Questions and answers