F97CMN and G97CMN: Installation, Start-up, Operating and Service and Maintenance Instructions
Table 4 – Minimum Space Volumes for 100% Combustion, Ventilation and Dilution Air from Outdoors
OTHER THAN FAN-ASSISTED TOTAL
(1,000'S BTUH GAS INPUT RATE)
30
40
ACH
1,050 (29.7)
1,400 (39.6)
0.60
0.50
1,260 (35.6)
1,680 (47.5)
0.40
1,575 (44.5)
2,100 (59.4)
2,100 (59.4)
2,800 (79.2)
0.30
3,150 (89.1)
4,200 (118.9)
0.20
6,300 (178.0) 8,400 (237.8) 10,500 (297.3) 8,400 (237.8) 9,000 (254.6) 12,000 (339.5) 15,000 (424.4) 18,000 (509.2) 21,000 (594.1)
0.10
0.00
NP
NP
NP = Not Permitted
Fig. 6 – Air for Combustion, Ventilation, and Dilution for Outdoors

CONDENSATE TRAP

Condensate Trap-Upflow Orientation
When the furnace is installed in the upflow position, it is not necessary
to relocate the condensate trap or associated tubing. Refer to
upflow condensate trap information. Refer to Condensate Drain section
for information how to install the condensate drain.
Condensate Trap-Downflow Orientation
When the furnace is installed in the downflow position, the condensate
trap will be initially located at the upper left corner of the collector box,
as received from the factory. See the top image in
furnace is installed in the downflow orientation, the condensate trap
must be relocated for proper condensate drainage. See the bottom image
in
Fig.
8.
To Relocate the Condensate Trap:
• Orient the furnace in the downflow position.
Fig. 8
shows the condensate trap and tubing before and after
relocation. Refer to
Fig. 8
To begin the trap conversion.
• Refer to Condensate Drain section for information how to install the
condensate drain.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
50
40
Space Volume Ft3 (M3)
1,750 (49.5)
1,400 (39.6)
2,100 (59.4)
1,680 (47.5)
2,625(74.3)
2,100 (59.4)
3,500(99.1)
2,800 (79.2)
5,250(148.6)
4,200 (118.9) 4,500 (127.3)
NP
NP
L12F012
Fig. 7
for
Fig.
8. When the
FAN-ASSISTED TOTAL
(1,000'S BTUH GAS INPUT RATE)
60
80
1,500 (42.5)
2,000 (56.6)
1,800 (51.0)
2,400 (67.9)
2,250 (63.7)
3,000 (84.9)
3,000 (84.9)
4,000 (113.2)
6,000 (169.8)
NP
NP
Condensate Trap
Relief Port
Collector Box
Plugs
Fig. 7 – Upflow Trap Configuration
(Appearance May Vary)
Fig. 8 – Downflow Trap Configuration
(Appearance May Vary)
9
100
120
2,500 (70.8)
3,000 (84.9)
3,000 (84.9)
3,600 (101.9)
3,750 (106.1)
4,500 (127.3)
5,000 (141.5)
6,000 (169.8)
7,500 (212.2)
9,000 (254.6)
NP
NP
Vent Pipe Clamp
Pressure Switch
Port
140
3,500 (99.1)
4,200 (118.9)
5,250 (148.6)
7,000 (198.1)
10,500 (297.1)
NP
Vent Elbow Clamp
Vent Elbow
Collector Box
Plug
Condensate Trap
Relief Port
Condensate Trap
Outlet
A11306
A11585A