Gas Piping - Tempstar F97CMN Installation, Start-Up, Operating And Service And Maintenance Instructions

Modulating, high efficiency condensing gas furnace, 4-way multipoise
Table of Contents

Advertisement

F97CMN and G97CMN: Installation, Start-up, Operating and Service and Maintenance Instructions
Table 7 – Cooling
Unit Size: 1202422
Clg/CF Switch settings
Clg Switches
SW2-3
Clg Default:
OFF
CF Switches
SW3-3
Low-Clg Default:
OFF
OFF
OFF
OFF
Cooling Airflow
ON
(SW2)
Low-Cooling
ON
Airflow (SW3)
ON
ON
Maximum Clg Airflow
CF Switches
SW3-3
Cont. Fan Default:
OFF
OFF
OFF
OFF
Continuous Fan
ON
Airflow (SW3)
ON
ON
ON
Maximum Heat Airflow
Heating (SW1)
Intermediate Heat Airflow
Minimum Heat Airflow
See Notes following table.
NOTES:
1.Nominal 350 CFM/ton cooling airflow is delivered with SW1-5 and SW4-3 set to OFF.
Set SW1-5 to ON for nominal 400 CFM/ton (+15% airflow).
Set SW4-3 to ON for nominal 325 CFM/ton (-7% airflow).
Set both SW1-5 and SW4-3 to ON for nominal 370 CFM/ton (+7% airflow).
This applies to Cooling and Low-Cooling airflow, but does not affect continuous fan airflow.
The above adjustments in airflow are subject to motor horsepower range/capacity.
2.Maximum cooling airflow is achieved when switches SW2-1, SW2-2, SW2-3 and SW1-5 are set to ON, and SW4-3 is set to OFF.
3.All heating CFM's are when low/medium heat rise adjustment switch (SW1-3) and comfort/efficiency adjustment switch (SW1-4) are both set to OFF.
4.Ductwork must be sized for high-heating CFM within the operational range of ESP. Operation within the blank areas of the chart is not
recommended because high-heat operation will be above 1.0 ESP.
5.All airflow on 21" casing size furnaces are 5% less on side return only installations.
6.Return air above 1800 CFM on 24.5" casing sizes requires two sides, one side and bottom or bottom only, to allow sufficient airflow to the furnace.

GAS PIPING

WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death,
and/or property damage.
Never purge a gas line into a combustion chamber. Never test for gas
leaks with an open flame. Use a commercially available soap solution
made specifically for the detection of leaks to check all connections. A
fire or explosion may result causing property damage, personal injury
or loss of life.
Use proper length of pipe to avoid stress on gas control manifold and
gas valve.
Gas valve inlet and/or inlet pipe must remain capped until gas supply
line is permanently installed to protect the valve from moisture and
debris. Also, install a sediment trap in the gas supply piping at the inlet
to the gas valve.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
4
and Heating Air Delivery - CFM (Bottom Return
(SW1-5 and SW4-3 set to OFF, except as indicated. See notes 1 and 2.)
SW2-2
SW2-1
0.1
OFF
OFF
1850
1855
SW3-2
SW3-1
OFF
OFF
930
OFF
ON
765
ON
OFF
930
ON
ON
1095
OFF
OFF
1265
1255
OFF
ON
1465
1455
ON
OFF
1850
1855
ON
ON
2200
2200
2
2200
2200
SW3-2
SW3-1
OFF
OFF
930
OFF
ON
765
ON
OFF
930
ON
ON
1095
OFF
OFF
1265
1255
OFF
ON
1465
1455
ON
OFF
1465
1455
ON
ON
1465
1455
3
1815
1820
3
1095
3
905
External Static Pressure (ESP)
0.2
0.3
0.4
0.5
1860
1855
1850
925
915
900
885
745
740
705
680
925
915
900
885
1100
1110
1105
1085
1265
1280
1275
1470
1465
1465
1860
1855
1850
2200
2190
2185
2200
2190
2185
925
915
900
885
745
740
705
680
925
915
900
885
1100
1110
1105
1085
1265
1280
1275
1470
1465
1465
1470
1465
1465
1470
1465
1465
1825
1820
1815
1100
1110
1105
1085
900
890
875
855
FURNACE DAMAGE HAZARD
Failure to follow this caution may result in furnace damage.
Connect gas pipe to furnace using a backup wrench to avoid damaging
gas controls and burner misalignment.
In the State of Massachusetts:
1. Gas supply connections MUST be performed by a licensed
plumber or gas fitter.
2. When flexible connectors are used, the maximum length shall not
exceed 36 in. (915 mm).
3. When lever handle type manual equipment shutoff valves are
used, they shall be T-handle valves.
4. The use of copper tubing for gas piping is NOT approved by the
State of Massachusetts.
23
5
With Filter) (Continued)
0.6
0.7
0.8
1830
1805
1775
See note 4
See note 4
See note 4
See note 4
1285
1270
1260
1470
1455
1450
1830
1805
1775
2170
2145
2085
2170
2145
2085
See note 4
See note 4
See note 4
See note 4
1285
1270
1260
1470
1455
1450
1470
1455
1450
1470
1455
1450
1795
1775
1745
See note 4
See note 4
CAUTION
!
NOTICE
!
0.9
1.0
1750
1730
1250
1230
1435
1415
1750
1730
1990
1890
1990
1890
1250
1230
1435
1415
1435
1415
1435
1415
1720
1700