Tempstar F97CMN Installation, Start-Up, Operating And Service And Maintenance Instructions page 43

Modulating, high efficiency condensing gas furnace, 4-way multipoise
Table of Contents

Advertisement

F97CMN and G97CMN: Installation, Start-up, Operating and Service and Maintenance Instructions
HORIZONTAL LEFT-VERTICAL VENT CONFIGURATION
HORIZONAL LEFT-LEFT VENT CONFIGURATION
HORIZONTAL LEFT-RIGHT VENT CONFIGURATION
Fig. 54 – Horizontal Left (Appearance may vary)
See "Notes for Venting Options"
HORIZONTAL RIGHT-VERTICAL VENT CONFIGURATION
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
A11327A
HORIZONTAL RIGHT-LEFT VENT CONFIGURATION
A11328A
HORIZONTAL RIGHT-RIGHT VENT CONFIGURATION
Fig. 55 – Horizontal Right (Appearance may vary)
See "Notes for Venting Options"
NOTES FOR VENTING OPTIONS
1. Attach vent pipe adapter with gasket to furnace casing.
2. Align notches in rubber coupling over standoffs on adapter. Slide
clamps over the coupling.
3. Slide vent pipe through adapter and coupling into vent elbow.
4. Insert vent pipe into vent elbow.
5. Torque all clamps 15 lb.-in.
6. Attach combustion air pipe adapter with gasket to furnace.
A11329A
7. Attach combustion air pipe to adapter with silicone. Pilot drill a
1/8-in. hole in adapter and secure with a #7 x 1/2-in. sheet metal
screw.
A11337
43
A11336
A11335