Brinkmann 810-2455-G Owner's Manual page 6

4 burner gas grill
Table of Contents

Advertisement

Available languages

Available languages

LP GAS CYLINDER (TANK) SPECIFICATIONS:
LP gas cylinder (not supplied with this grill)
The LP (Liquid Propane) gas cylinder specifically designed to be used with this grill must be 12" (30 .5
cm) diameter x 18" (45 .7 cm) tall and have a 20 lb . (9 .1 kg) capacity incorporating a Type 1 cylinder valve
and an over-filling protection device (OPD) .
This grill is designed to fit Worthington, Manchester or SMPC brand 20 lb . (9 .1 kg) cylinders . Other brand
DOT cylinders may fit this grill if the cylinder has similar dimensions of the top and bottom rings .
The installation of this appliance must be in accordance with:
All applicable local codes, or in the absence of local codes, either:
• National Fuel Gas Code ANSI Z223.1 NFPA 54
• Natural Gas and Propane Installation Code: CAN/CGA B149.1
• Natural Gas Installation Code: CAN/CGA B149.1 (Canada)
• Propane Installation Code: CAN/CGA B149.2 (Canada)
To check your local codes, see your local LP gas dealer or natural gas company . This grill was not
intended to be connected to a natural gas supply line . If an external electrical source is utilized, it must be
electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA 22.1.
When purchasing or exchanging a cylinder for your gas grill, it must be constructed and marked in
accordance with the specifications for LP gas cylinders of the U .S . Department of Transportation (DOT)
or the National Standard of Canada, CAN/CSA-B339 Cylinders, Spheres and Tubes for Transportation
of Dangerous Goods; and Commission, as applicable; and provided with a listed over-filling prevention
device (OPD), and provided with a cylinder connection device compatible with the connection for outdoor
cooking appliances .
The cylinder must also be equipped with:
• A shut-off valve terminating in a Type 1 gas cylinder valve outlet.
• A Type 1 valve that prevents gas flow until a positive seal is obtained.
• An arrangement for vapor withdrawal.
• A collar to protect the cylinder shut-off valve.
• A safety relief device having direct communication with the vapor space of the cylinder.
• A listed over-filling prevention device (OPD).
FILLING THE LP GAS CYLINDER (TANK):
• Allow only qualified licensed LP gas dealers to properly fill or repair your LP gas cylinder.
• New tanks should be purged prior to filling; inform LP gas dealer if you are using a new tank.
• DO NOT allow the cylinder to be filled beyond 80% capacity. Over-filled tanks can create a
dangerous condition. Over-filled tanks can build-up pressure and cause the relief valve to expel
propane gas vapors. The vapor is combustible and if it comes in contact with a spark source or
flame an explosion causing severe burns, bodily harm, or death could occur.
• Always use a protective cylinder cap when grill is not connected to cylinder.
• If you exchange a cylinder with a qualified exchange program, the new cylinder must have
a Type 1 valve and an over-filling prevention device (OPD).
• Inspect the propane tank valve rubber seal for cracks, wear or deterioration prior to use. A
damaged rubber seal can cause a gas leak, possibly resulting in an explosion, fire or severe
bodily harm.