Download Print this page

Omron H8PS-8AF Manual page 30

Cam positioner

Advertisement

Bank Switching Method (f8)
The following methods can be used to switch the bank: the bank
inputs on the terminal block or the BANK Key on the front of the Cam
Positioner. The method is set using the F8 menu in the Function
Setting Mode.
Setting
Display
Bank input
Banks can be changed only with the bank
in
(IN)
inputs. Even if a different bank number is
displayed in Programming Mode, the bank
specified with the bank inputs will be used
after switching to Run Mode or Test Mode.
key
Bank Key
Banks can be changed only with the
(KEY)
BANK Key. Bank inputs are disabled.
Note: 1. Default settings are shown in reverse type.
2. This setting can be made only when the Bank Function (F7)
has been enabled.
Setting Display
PRG
CAM
STEP
The bank inputs on the terminal block are used as shown in the
following table.
Bank No.
0
OFF
1
ON
2
OFF
3
ON
4
OFF
6
ON
6
OFF
7
ON
ON: Shorted to COM terminal.
OFF: Open
E24 Detection (f10)
Displaying E24 errors (Encoder disconnected) can be disabled. The
setting does not normally need to be changed. When the Y92C-30
Parallel Input Adapter (order separately) is used to connect more
than one H8PS to the same Encoder, an E24 error can appear even
if the Encoder connection is normal. If this happens, use the E24
Detection function (F10) in the Function Setting Mode to disable E24
detection displays.
Setting
Display
Enabled
An E24 error will be displayed if the
yes
Encoder is not connected correctly in
Run Mode or Test Mode.
no
Disabled
An E24 error will not be displayed
even if an Encoder is not connected.
Note: Default settings are shown in reverse type.
Description
Use the ANGLE Keys
to set
the bank switching method.
in
key
(IN)
(KEY)
Bank input terminals
1
2
4
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
Description
Bank Copy (f9)
Programs can be copied between banks. This function is convenient
to copy a program to a different bank when only some of the ON/OFF
angle settings need to be changed.
Note: This operation can be used only when the Bank Function (F7)
has been enabled.
Example: Copying the Program in Bank 2 to Bank 3
Banks are copied using the F9 menu in the Function Setting Mode.
Setting Display
1. Set the number of the bank to be copied.
PRG
STEP
CAM
2. Set the number of the bank to receive the copy.
PRG
CAM
STEP
3. Execute the copy.
PRG
CAM
STEP
4. Copying completed.
PRG
CAM
STEP
Setting Display
PRG
CAM
STEP
H8PS
Set bank number 2 (the copy
source) with the
Key and
BANK
then press the
Key.
WRITE
Set bank number 3 (the copy
destination) with the
Key and
BANK
then press the
Key.
WRITE
Confirm that cpy is displayed and
then press the
Key again.
WRITE
After completion of copying end is
displayed for approx. 1 s and the
previous display will be resumed.
Enable or disable E24 detection
with the ANGLE Keys
.
yes
no
(Enabled)
(Disabled)
30

Advertisement

loading