Cam positioner

Advertisement

Setting ON/OFF Angles Using Support
Software
With 16-/32-output models, programs can be uploaded or
downloaded easily with the optional Support Software (H8PS-SOFT-
V1) by connecting a personal computer to the Cam Positioner using
the USB cable (Recommended USB Cables: ELECOM CO.Ltd.
U2C-MF20BK).
Support Software Functions
• Writing cam programs
• Setting functions
• Editing, saving, and printing programs
• Displaying and printing cam program operation charts
• Simple simulations of programs
Applicable OS: Windows 98, 2000, ME, or XP
Refer to the user's manual for the Support Software for details.
Checking Timing (Test Mode)
Testing Operation
Operation can be tested to check operation timing.
• Set the mode switch to TEST.
Mode
PRGM
TEST
RUN
• Operate the Encoder and check the timing of operation.
1
2
7
TST
CAM
STEP
• If the timing is not correct, change the ON/OFF angle settings.
The settings can be changed in Test Mode.
Note: 1. Outputs will turn ON and OFF in Test Mode. Confirm system
safety before switching to Test Mode.
2. With 16-/32-output model, be sure to turn ON the start input.
Outputs are not turned ON unless the start input is turned
ON.
H8PS
Present angular position
ON/OFF angle setting
23

Advertisement