DB68-06031A-01_A5.indd 21
good'sleep function
Use the good'sleep function to get a good sleep at night and to save
energy. You can select this function both in the Cool and Heat modes.
In the Cool or
Heat mode
(Set the operation time.)
• Press the
(Timer) button to change the current function
between On, Off, and
NOTE
• You can adjust the set temperature by 1 °C between 16 °C and 30 °C.
• The recommended and optimal set temperatures in the good'sleep
function are as follows:
Recommended set
Mode
temperature
Cool
25 °C to 27 °C
Heat
21 °C to 23 °C
• Once you start the good'sleep function, the Timer (
appears on the indoor unit display.
• You can set the operation time to between 0.5 and 12 hours. Set the
operation time to 0.0 to cancel the good'sleep function.
• The default operation time for the good'sleep function in the
Cool mode is 8 hours. If the operation time is set to over 5 hours,
the Wake up function begins 1 hour before the set time. The air
conditioner stops automatically when the operation time expires.
• When the Timed on, Timed off, and good'sleep functions are
overlapped, the air conditioner operates its timer with only the
function that you have started most recently.
(Select
among On, Off, and
(good'sleep).
Optimal set
temperature
26 °C
22 °C
.)
) indicator
English