Advertisement

A3050 EU_IM_DB68-04212A_HP_EN.indd 1
2013-10-23 16:31:10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AR**HSFS Series and is the answer not in the manual?

Questions and answers

Claudia Carniel
June 25, 2025

Manuale utente conditioners samsung AR

Summary of Contents for Samsung AR**HSFS Series

  • Page 1 A3050 EU_IM_DB68-04212A_HP_EN.indd 1 2013-10-23 16:31:10...
  • Page 2: Table Of Contents

    Contents Installation Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Choosing the installation location .
  • Page 3: Safety Precautions

    In order to help prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact  SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy. Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations ...
  • Page 4: Choosing The Installation Location

    Safety precautions After completing the installation, always carry out a functional test and provide the instructions on how to operate the air  conditioner to the user. Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to ...
  • Page 5: Outdoor Unit

    Outdoor Unit Where it is not exposed to strong wind  Well ventilated and dustless places  Where possible keep out of sunlight and rain  Where neighbors are not annoyed by operation sound or hot air  Solid wall or support that prevents vibration and is strong enough to hold the product weight ...
  • Page 6 Choosing the installation location Space Requirements for Outdoor Unit If using a multi system, install as described in the installation manual supplied with the outdoor unit. When installing 1 outdoor unit  Figure Description Top view Side view Air intake Air outlet Air intake Air outlet...
  • Page 7: Accessories

    (Unit : mm)  When the walls are blocking front and the rear side of the outdoor  When the upper part of the outdoor unit and units the air outlet is opposite the wall 300 or more 600 or more 600 or more ...
  • Page 8 Accessories Accessories in the outdoor unit case If using a multi system, refer to the manual supplied with the outdoor unit. 2-wire 3-wire Drain Plug (1) Rubber Leg (4) Assembly Cable (1) Assembly Cable (2) • The flare nuts are attached to the end of each pipe of an evaporator or a service port. Use the nuts when connecting the pipes.
  • Page 9: Fixing The Installation Plate

    Fixing the installation plate You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.
  • Page 10: Disassembling/Assembling The Cover Panel For Indoor Unit Installation

    Disassembling/Assembling the Cover panel for indoor unit installation Please scan this QR code for detail video of indoor unit installation . In order to install the indoor unit, you must disassemble the cover panel first . Please proceed following instructions to disassemble and assemble the cover panel . Hooks (on the cover panel) may get damaged if you apply excessive force as you disassemble and assemble the cover panel .
  • Page 11 f Removing the hooks on the side f Removing the hooks on the central part ① ② ①  Caution (fragile)  Caution (fragile) - Gently press the both side of the cover - Use both hands panel inwards (①) and release the hooks - Release each hook by pushing it up at an angle .
  • Page 12: Connecting The Assembly Cable

    Connecting the assembly cable Cable specification If using a multi system, install as described in the installation manual supplied with the outdoor unit. Model Power cable Interconnection cable Type GL 3G1.0mm ² H07RN-F 3G1.5mm ² H07RN-F 09/12 2x0.75mm ² H05RN-F 3G1.0mm ²...
  • Page 13 2 . Open the cover panel. 3 . Remove the screw securing the connector cover. 4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below) •...
  • Page 14: Installing And Connecting The Assembly Pipe Of The Indoor Unit

    Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa.
  • Page 15: Evacuating The Indoor Unit

    Assembling the hanger screw Use 2 screws to fix the indoor unit as shown in the picture .  Screw(M4x10) Evacuating the indoor unit The indoor unit is supplied with inert gas (nitrogen). Before installing the unit, check if nitrogen gas flow out of indoor unit. If this one isn’t true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit.
  • Page 16 Cutting or extending the pipe 1. Make sure that you have all the required tools (pipe cutter, reamer, flaring tool and pipe holder). 2. If you want to shorten the pipe, cut it using a pipe cutter, ensuring that the cut edge remains at 90° with the side of the pipe (see below examples of correct and incorrect cut edges).
  • Page 17: Installing And Connecting The Drain Hose Of The Indoor Unit

    Installing and connecting the drain hose of the indoor unit When installing the drain hose for the indoor unit, check if condensation draining is adequate. When passing the drain hose through the 65 mm hole drilled in the wall, check the followings: Wall Indoor unit Drain hose...
  • Page 18: Changing Direction Of The Drain Hose

    Installing and connecting the drain hose of the indoor unit 6. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight. Shield 7. Pass the drain hose through the hole in the wall. Check if it slants downwards as seen in the picture.
  • Page 19: Installing And Connecting The Drain Hose Of The Outdoor Unit

    Installing and connecting the drain hose of the outdoor unit While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following. 1. Insert the drain plug into the drain hole on the underside of the outdoor unit. •...
  • Page 20: Adding Refrigerant

    Evacuating the connected pipes Outdoor unit Indoor unit 1. Connect each assembly pipe to the appropriate valve on the outdoor unit and Gas pipe side tighten the flare nut. 2. Tighten the flare nut first with your hands, and then with a torque wrench, Liquid pipe side applying the following torque.
  • Page 21 Important information regulation regarding the refrigerant used This product contains fluorinated greenhouse gases covered by the Kyoto Refrigerant type GWP value Protocol. R-410A 1975 Do not vent gases into the atmosphere.  GWP=Global Warming Potential 1. Please fill in with indelible ink, Contains fluorinated greenhouse gases ...
  • Page 22: Performing The Gas Leak Tests

    Performing the gas leak tests If using a multi system, install as described in the installation manual supplied with the outdoor unit. Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate).
  • Page 23: Fixing The Indoor Unit In Place

    Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priory. After checking for gas leaks in the system, insulate the pipe, hose and cables. Insulation Then place the indoor unit on the installation plate. 1.
  • Page 24: Smart Install Mode

    Smart Install mode If using a multi system, install as described in the installation manual supplied with the outdoor unit. This model supports Smart Install mode which checks installation status to find out if there is any problems with any of the functions .
  • Page 25 2) Smart Install mode in progress • 88 Display : Progress will be diplayed in 0~99 . • LED Display : Indicator on the indoor unit display will blink in sequence and then all indicators will blink . (This will be repeated .
  • Page 26: Final Check And Trial Operation

    Final check and trial operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the followings: • Strength of the installation site • Tightness of pipe connection to detect gas leak •...
  • Page 27: How To Connect Your Extended Power Cables

    How to connect your extended power cables Items to prepare (compressor and insulation tape should be prepared by an installation technician.) Tools Crimping pliers Connection sleeve (mm) Insulation tape Contraction tube (mm) Spec MH-14 20xØ7.0(HxOD) Width 18 mm 50xØ8.0(LxOD) Shape 1.
  • Page 28: Sub Pcb Installation(Optional)

    Sub PCB installation(optional) Only for multi system (Wried remote controller, central remote controller etc.) 1. Turn the power off and take off the cover panel of the indoor unit. 2. Attach the Sub PCB to the Case Sub PCB. 3. Assemble the Case Sub PCB to the indoor unit. Case Sub PCB Sub PCB 4.
  • Page 29 English-29 A3050 EU_IM_DB68-04212A_HP_EN.indd 29 2013-10-23 16:31:18...
  • Page 30 DB68-04212A-00 A3050 EU_IM_DB68-04212A_HP_EN.indd 30 2013-10-23 16:31:18...
  • Page 31 This manual is made with 100% recycled paper. imagine the possibilities imagine the possibilities Thank you for purchasing this Samsung product. Thank you for purchasing this Samsung product. To receive more complete service, please To receive more complete service, please register your product at register your product at www.samsung.com/register...

This manual is also suitable for:

Ar**hssd seriesAr**hsfn series

Table of Contents