Installation - Xantrex XPF 35-10 Operating Manual

Xpf series dual output 35v 10a powerflex dc power supply
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 37
Mains Operating Voltage
Check that the instrument operating voltage marked on the rear panel is suitable for the local
supply. Should it be necessary to change the operating voltage, proceed as follows:
1.
Ensure that the instrument is disconnected from the AC supply.
2.
Remove the 6 screws holding the case upper and lift off the cover.
3.
Change the plug-in connections between the transformer and main board following the
diagram below:
(P ARK)
4.
Re-assemble in the reverse order.
5.
To comply with safety standard requirements the operating voltage on the rear panel must
be changed to clearly show the new voltage setting.
Mains Lead
When a three core mains lead with bare ends is provided this should be connected as follows:
BROWN
BLUE
GREEN/YELLOW -
When fitting a fused plug a 5 amp fuse should be fitted inside the plug. As the colours of the
wires in the mains lead of this apparatus may not correspond with the coloured markings
identifying the terminals in your plug proceed as follows:
The wire which is coloured green-and-yellow must be connected to the terminal in the plug which
is marked by the letter E or by the safety earth symbol shown above or coloured green or green-
and-yellow.
The wire which is coloured blue must be connected to the terminal which is marked with the letter
N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked with the
letter L or coloured red.
Any interruption of the mains earth conductor inside or outside the instrument will make the
instrument dangerous. Intentional interruption is prohibited.
Mounting
This instrument is suitable both for bench use and rack mounting. It is delivered with feet for
bench mounting. The front feet include a tilt mechanism for optimal panel angle.
230V OPERA TION
(VIEW FROM ABO VE)
RED
BRO W N
L
P
N
-
MAINS LIVE
-
MAINS NEUTRAL
EARTH
WARNING! THIS INSTRUMENT MUST BE EARTHED.
BLUE
Safety Earth Symbol

Installation

115V OPERA TION
(VIEW FROM ABO VE)
BRO W N
RED
L
P
N
(P ARK)
BLUE
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents