Delmhorst F-2000H Operation Manual

Delmhorst F-2000H Operation Manual

Hay and hops moisture meter

Advertisement

Quick Links

F-2000H
HAY AND HOPS MOISTURE METER
OPERATION MANUAL – v3.6
DELMHORST EUROPE
TITANIUMLAAN 100
NL 5221 CK 's-HERTOGENBOSCH
THE NETHERLANDS
info@delmhorst.eu
www.MoistureMetersDelmhorst.com
+31 (0)73 6395080

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F-2000H and is the answer not in the manual?

Questions and answers

Summary of Contents for Delmhorst F-2000H

  • Page 1 F-2000H HAY AND HOPS MOISTURE METER OPERATION MANUAL – v3.6 DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK ‘s-HERTOGENBOSCH THE NETHERLANDS info@delmhorst.eu www.MoistureMetersDelmhorst.com +31 (0)73 6395080...
  • Page 2: Table Of Contents

    Model F-2000/H Owners Manual TABLE OF CONTENTS F-2000 Features Before You Begin Button Functions Check Calibration Set Scale Change The Set Point To Check The Accumulated Readings To Reset The Meter Taking A Reading Testing Baled Hay Testing in the Windrow Factors Affecting Your Reading Range Of Moisture Content Hay Temperature...
  • Page 3: Before You Begin

    FEATURES  8% to 40% moisture range for alfalfa hay  8% to 23% moisture range for hops  Digital readout  Built-in calibration check  Temperature stable circuit  Ergonomic case design  Includes (1) 9-volt battery  Three year warranty ...
  • Page 4: Check Calibration

    If this occurs, change the battery immediately. Continued use with a low battery may cause the meter to go out of calibration. If you have a fresh battery and the instrument still does not indicate an acceptable calibration, return it to DELMHORST for service. See “Service for Your Meter” section.
  • Page 5: To Reset The Meter

     To erase all the accumulated readings, hold the calibration check button (#2) for more than five seconds until the meter displays “0.”  To keep the accumulated readings in memory, release the calibration check button (#2) before the total cycle time is complete. The meter will accumulate up to 100 readings.
  • Page 6 Test A:  Attach the #831 short pin prod to the H-4 handle and connect the handle to the external connector on top of the meter.  Prepare a representative sample by collecting hay from various parts of the windrow. ...
  • Page 7: Factors Affecting Your Reading

    The F-2000 is designed to test moisture in hay over a range of 8%-40%. Readings over 30% should be used only as a qualitative indication of high moisture content. Delmhorst moisture meters use the relationship existing between electrical conductivity and moisture content in hay.
  • Page 8: Curing

    CURING Before proper curing has taken place, wide variations in moisture content should be expected in both recently baled hay and hay in the windrow. These variations will be exposed by meter readings taken on different parts of the windrow or bale. The higher the moisture range, the wider are the variations.
  • Page 9 Testing Hops – set meter to scale no 2 The F-2000 enables you to easily check moisture levels in baled hops to assure quality and safe storage. When measuring moisture content, keep in mind the average moisture content is not necessarily a true indication of the safety for storage, as a few wet spots in the hops can cause considerable damage.
  • Page 10: Care Of Your Meter

    CARE OF YOUR METER To keep your meter in good working order:  Store your meter in a clean, dry place. The protective carrying case provided is an ideal storage place when the meter is not in use.  Change the 9-Volt battery as needed. Continued use with a low battery may cause the meter to go out of calibration.
  • Page 11: Warranty

    At our option we may replace or repair the meter. DELMHORST shall not be liable for incidental or consequential damages for the breach of any express or implied warranty with respect to this product or its calibration.
  • Page 12: Declaration Of Conformity

    DECLARATION OF CONFORMITY Manufacturer's Name: Delmhorst Instrument Co. Manufacturer's Address: 51 Indian Lane East Towaco, NJ 07082 Council Directive(s): 89/336/EEC - Meets EMC directive 73/23/EEC - Not required. Voltage used or generated is not within scope of Low Voltage Directive.