F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 1
F-2000
o w n e r ' s m a n u a l
®
.
TM
W H E N A C C U R A C Y I S T H E P O I N T

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F-2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Delmhorst F-2000

  • Page 1 F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 1 F-2000 o w n e r ’ s m a n u a l ® W H E N A C C U R A C Y I S T H E P O I N T...
  • Page 2 F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 2...
  • Page 3: Table Of Contents

    F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 3 TABLE OF CONTENTS 2 F-2000 Features 3 Before You Begin 3 Check Calibration 4 Change the Set-Point 4 Information About Your Readings 5 To Check Accumulated Readings 5 To Reset Meter...
  • Page 4: F-2000 Features

    F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 4 D E L M H O R S T F - 2 0 0 0 Connector Digital Readout Set-Point Read Key Calibration Check Key Set Point Decrease F-2000 FEATURES...
  • Page 5: Before You Begin

    F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 5 BEFORE YOU BEGIN Key Functions READ KEY - Reads the Percent Moisture Content Value. CALIBRATION CHECK KEY - When pressed with the read key checks the meter calibration. It also displays the number of readings in mem- ory (up to 100), the average, and the highest stored reading.
  • Page 6: Change The Set-Point

    F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 6 CHANGE THE SET-POINT hTo change the set-point value press the set-point key The meter will display the current set-point value. hTo scroll forward to a higher value, hold the set-point key while the current value is displayed and scroll to the set-point value desired.
  • Page 7: To Check Accumulated Readings

    F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 7 TO CHECK ACCUMULATED READINGS This feature allows you to view the total number of all accumulated readings, the average of those readings, and the highest stored reading. hTo view the statistics press and release the calibration check key .
  • Page 8: Taking A Reading

    F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 8 TAKING A READING Testing Baled Hay hConnect the bale prod to the connector on the top of the meter. hInsert the bale prod into the bale. hPress the read key The meter displays the %MC for two seconds.
  • Page 9 F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 9 Test A hAttach the #831 short pin prod to the H-4 handle and connect the handle to the external connector on top of the meter. hPrepare a representative sample by collecting hay from various parts of the windrow.
  • Page 10: Factors Affecting Your Reading

    Range of Moisture Content The F-2000 is designed to test moisture in hay over a range of 6%-40%. Readings over 30% should be used only as a qualitative indication of high moisture content. Delmhorst moisture meters use the relationship existing between electrical conductivity and moisture content in hay.
  • Page 11: Hay Temperature

    F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 1 Hay Temperature The F-2000 has been calibrated at 80°F on various samples of different types of hay, mostly alfalfa, and on different cuttings and mixtures. The higher the temperature of the sample, the higher the meter readings will be.
  • Page 12: Density

    F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 1 Density The calibration of the moisture testers applies to bales of normal “average” density. Generally: hDenser bales may yield readings 1-2% higher. hLooser bales tend to yield 1-2% lower.
  • Page 13: Care Of Your Meter

    F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 1 CARE OF YOUR METER To keep your meter in good working order: hStore your meter in a clean, dry place. The optional protective carrying case is an ideal storage place when the meter is not in use.
  • Page 14: Service For Your Meter

    F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 1 SERVICE FOR YOUR METER If your meter is not working properly, replace the battery with a new one and check the calibration. If this does not resolve the problem, go to www.delmhorst.com and follow the instructions under the Product Support tab.
  • Page 15: Warranty

    F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 1 WARRANTY Delmhorst Instrument Co., referred to hereafter as Delmhorst, guarantees its F-2000 meter for three years from date of purchase and any optional electrodes against defects in material or workmanship for 90 days. If, within the...
  • Page 16 F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 1 For more than 65 years Delmhorst Instrument has been the leading manufacturer of high quality, US- made moisture meters and thermo- hygrometers. Today we offer a wide range of meters for applica-...