Programming The Control - GE PNSF35B Owner's Manual And Installation Instructions

Water softening system
Hide thumbs Also See for PNSF35B:
Table of Contents

Advertisement

Programming the Control

CONTROL SETTINGS REQUIRED upon installation and
after an extended power outage.
NOTES:
• WHEN THE TRANSFORMER IS PLUGGED INTO THE
ELECTRICAL OUTLET (see step 9), 12:00 AM (flashing), and
PRESENT TIME show in the display area. Program the control as
instructed below. If SR - - is flashing, use the UP (+)
set the correct SR code as follows: SR17 for GXSF23 or SR35 for
PNSF35. If you pass by the correct code number, use the DOWN
(-)
button. Then press the SELECT button and program
the control.
• A "beep" sounds while pressing buttons for control programming.
One beep signals a change in the control display. Repeated beeps
mean the control will not accept a change from the button you
have pressed, and you should use another button.
• To program the control, you will use the UP (+)
and SELECT buttons.
SET PRESENT TIME OF DAY
NOTE: If the words PRESENT TIME do not show in the display,
press the SELECT button until they do.
1. Press the UP (+)
or DOWN (-)
moves the display ahead; the DOWN button moves the time
backward.
If the present time is between noon and midnight, be sure PM
shows
.
PM
PRESENT TIME
NOTE: Each press of an UP (+)
the time by one minute. Holding the button in changes the time
32 minutes each second
PRESENT TIME
2. When the present time shows, press SELECT to set. If the present
time is between midnight and noon, be sure AM shows.
SET WATER HARDNESS NUMBER
NOTE: If 15 (factory default) and
HARDNESS do not show in the
display, press SELECT until they do.
1. Press the UP (+)
or DOWN (-)
hardness number in the display. DOWN (-)
down to 1. UP (+)
moves the maximum setting.
NOTE: Each press of a button changes the display by 1 between 1 and
25. Above 25, the display changes 5 at a time (25, 30, 35, etc.). Holding
a button in changes the numbers twice each second.
2. When your water hardness number shows, press SELECT to set.
NOTE: If there is clear water iron in your water supply, you will need
to increase the hardness setting by 5 for each 1 ppm of clear water iron
in your water supply.
You can get the grains per gallon (gpg) hardness of your water supply
from a water analysis laboratory, or call and ask your local water
department, if you are on a municipal supply, or call GE Answer
®
Center
to request a water hardness test kit. If your report shows
hardness in parts per million (ppm) simply divide by 17.1 to get the
equivalent number of grains per gallon.
button to
, DOWN (-)
PM
PRESENT TIME
button to set. The UP button
or DOWN (-)
button changes
.
AM
HARDNESS
button to set your water
moves the display
SmartWater Softener System
Display
RECHARGE TONIGHT
TOUCH
or
RECHARGE NOW
HOLD
TOUCH or HOLD button
SET REGENERATION (STARTING) TIME
NOTE: RECHARGE TIME and a flashing 2:00 AM
(factory default) should show in the display. This is a good
time for regeneration to start (over in about 2 hours) in
most households because water is not in use. HARD
WATER is bypassed to house faucets during regeneration.
If no change is needed, go to step 2. To change the
regeneration starting time, follow step 1.
1. Press the UP (+)
desired regeneration start time.
NOTE: Each press of the buttons changes the time by
1 hour. Holding the buttons in changes the time twice
each second.
2. Press the SELECT button once more.
Be sure to observe the AM or PM, as
you did when setting the time of day.
The display shows the present time of day and
RECHARGE TONIGHT.
TIME
SELECT
HARDNESS
SELECT button
or DOWN (-)
button to set the
RECHARGE
TIME
PM
RECHARGE TONIGHT
UP (+)
button
DOWN (-)
button
AM
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gxsf23z01Gxsf23z

Table of Contents