Installer's Instructions - Vinotemp Wine-Mate WM-2520SSV-LA Operation Care Installation Manual

Advertisement

WARNING
Do not use a ground fault interrupter (GFI). A
dedicated circuit is required.
• Always check wiring harness connections before initiating any test procedures.
• Disconnect electric power from the appliance before performing any
• Voltage checks should be made by inserting meter proves beside the wires in
the connector blocks with the electric power source on and the connector block
• Resistance checks should be made on components with the electric power off
Federal law requires that WINE~MATE split cooling systems be
installed by an EPA certified refrigeration technician.
1. General Instructions
WINE~MATE split system is shipped as components and is ready for use only after
a certified refrigeration technician has properly installed the system. Proper
installation is critical. Vinotemp can only warrant the quality of the components. The
installation and proper operation of the system must be warranted by the installer.
Installation of the system must be done in accordance with all state and local
building and electrical codes.
The condensing unit and evaporator unit are connected by a liquid line and an
insulated suction line that are supplied by the installer. These lines must be properly
sized for the distance between the two units. After the units and lines are
connected, the system must be checked for restriction, pressurization and leak.
Then the system must be evacuate and charged with refrigerant. Refrigerant
amount will vary depending on the length of line set.
Parts included:
Temperature Controller
Evaporator Unit (liquid line solenoid valve and expansion valve are installed)
Condensing Unit (discharge, suction valves and pressure controls are installed)
Liquid Filter
Liquid Indicator

Installer's Instructions

WARNING
maintenance or repairs.
plugged in.
and the connector block disconnected.