Turn the main switch to ON.
•
Check the voltage (12V) on the Brown ca-
ble of the bulbholder connector.
4. Neutral switch cable.
•
Disconnect the neutral switch connector
from the wire harness and the bulbholder
connector.
•
Connect the pocket tester (Ω x 1) to the
neutral switch cable (on the harness side)
and the bulbholder connector (1).
The circuit is efficient.
IN COMPLIANCE WITH
SPECIFICATIONS (12V)
CONTINUITY
7-63
SIGNAL SYSTEM
OUT OF SPECIFICATION
The circuit from the main switch to the bulbhol-
der connector is defective. Repair.
DISCONTINUITY
The circuit from the bulb to the neutral switch
cable is defective. Repair.
ELEC