Montigo Homefire Plus MD38-BV Installation Operation & Maintenance Data page 8

Hide thumbs Also See for Homefire Plus MD38-BV:
Table of Contents

Advertisement

MD38-BV Homefire
MD38-BV
For Your Safety - READ BEFORE LIGHTING:
WARNING:
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
What To Do If You Smell Gas:
n
Do not try to light any appliance.
n
Do not touch any electrical switch; do not use any
phone in your building.
n
Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
f i r e - p a r t s . c o m
1. STOP! Read the safety information above on this label.
2. Flip down lower trims.
3. Push in gas control knob and turn clockwise
"OFF."
4. Wait five (5) minutes to clear out any gas. Smell for gas,
including near the floor. If you then smell gas, STOP!
Follow "B" in the safety information above on this label. If
you don't smell gas, go to the next step.
5. Locate pilot burner (See illustration at right.) and follow
steps below.
6. Turn knob on gas control counterclockwise
"PILOT."
Gas Control Knob
(Shown in "Pilot" postion.)
1. Turn off remote switch.
2. Flip down lower trim.
Page 8
Operation - Model MD38-BV
with Continuous Pilot
If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
Lighting Instructions:
to
to
NOTE: Knob cannot be turned from
"PILOT" to "OFF" unless knob is
pushed in slightly. Do not force.
To Turn Off Gas To Appliance:
n
If you cannot reach your gas supplier, call the Fire
Department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don't try to repair it, call a qualified service technician.
Force or attempt to repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system, and
any gas control which has been under water.
7. Push in gas control knob completely and hold. Light with
Piezo Igniter button. Continue to hold the control knob in for
about (1) minute after the pilot is lit. Release the knob and it
will pop back up. Pilot should remain lit. If it goes out repeat
steps 3 through 8.
n
If knob does not pop up when released. Stop and
immediately call your service technician or gas supplier.
n
If the pilot will not stay lit after
several tries, turn the gas
control knob to "OFF" and
call your service technician
or gas supplier.
8. Push in gas control knob and
turn counterclockwise
9. Flip up lower trim.
10.Turn on remote switch to ignite fire.
3. Push in gas control knob slightly and turn
to "Off". Do not force.
4. Flip up lower Trim.
to "ON."
clockwise

Advertisement

Table of Contents
loading

Table of Contents