1-116-010 Center Temp. 1
Specifies the temperature correction for the heating roller (center) when the paper
width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-018.
1-116-011 Ends Temp. 1
Specifies the temperature correction for the heating roller (ends) when the paper width
is 226 mm or more.
The start time of this SP can be adjusted with SP1116-018.
1-116-012 Center Temp. 2
Specifies the temperature correction for the heating roller (center) when the paper
width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-019.
1-116-013 Ends Temp. 2
Specifies the temperature correction for the heating roller (ends) when the paper width
is 226 mm or more.
The start time of this SP can be adjusted with SP1116-019.
1-116-018 Control Time 1
Specifies the start time of the temperature correction that is set with SP1116-010 and
-011.
The temperature correction is added when the time specified with this SP has passed
after feeding the paper.
1-116-019 Control Time 2
Specifies the start time of the temperature correction that is set with SP1116-012 and
-013.
The temperature correction is added when the time specified with this SP has passed
after feeding the paper.
022 to
Specifies the temperature correction for the heating roller (center and ends) when the
middle thick or other paper is used.
033
*ENG
[-10 / 10 / 0 / 1 deg/step]
*ENG
[-10 to 10 / 0 / 1 deg/step]
*ENG
[-10 to 10 / 0 / 1 deg/step]
*ENG
[-10 to 10 / 0 / 1 deg/step]
*ENG
[0 to 250 / 0 / 1 sec/step]
*ENG
[0 to 250 / 0 / 1 sec/step]